User manual ZANUSSI ZHC96X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZHC96X. We hope that this ZANUSSI ZHC96X user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI ZHC96X.


Mode d'emploi ZANUSSI ZHC96X
Download
Manual abstract: user guide ZANUSSI ZHC96X

Detailed instructions for use are in the User's Guide.

[. . . ] · No. 1 splashback B (optional) 2 Fig. 1 G C S G I A P1 B R P 14 GB Installation instructions · · · · · For easy installation, proceed as follows: Fix the wall brackets and Splashback Fix the canopy Connect the hood to the mains power supply and make sure that it works properly Set the hood for ducting or recirculation Fix the telescopic chimney Fitting the wall brackets and Splashback Please refer to (fig. 2a-b): · Draw a vertical line on the wall, from the centre of the cooking appliance up to the ceiling, using a marking pen. This is to ensure the correct vertical alignment of the various parts. · Fixing the wall brackets d = 1030 min 2 1 232 X 1 260 Fig. [. . . ] If the splashback is to be fixed to the wall using both the top and bottom fixing holes, care must be taken to ensure that the splashback is fitted at the correct height before fixing the base units or at least the worktop covering them. As this is a complex operation, it should only be undertaken by the technician installing the kitchen units or by a competent person who knows the final dimensions of the units. If the splashback is to be fixed through the top fixing holes only, proceed as follows: · Rest the splashback on the worktop and against the wall, as illustrated in fig. 2 . · Mark the centres of the two holes in the top surface. · Drill the wall using an 8 mm drill bit, and fix the splashback using the rawl plugs and screws provided. · If necessary, the installer should secure the splashback to the wall by tucking the bottom edge down behind the rear of the worktop. S1 S1 Fig. 3 1 1 1 Fixing the canopy Before starting to fix the canopy it will be necessary to adjust the support brackets S1 by turning the adjustment screws in a clockwise direction until their reach their limit (Fig. 3): · Hook the canopy onto the two size 4. 2 x 44. 4 screws 1 fitted as described above (Fig. 4 ). · Level the hood by turning the adjustment screws and then locking them. Fig. 4 Electrical connection and working test · Before connecting to the mains supply ensure that the mains voltage corresponds with the voltage on the rating plate inside the hood. · Connect the cooker hood to the mains via a double pole switch which has 3 mm clearance between the contacts. · Once the electrical connection has been completed, check that worktop illumination, motor and speed work properly. A Fig. 5 16 GB Ducting or Recirculation fitting · Ducting fitting · The hood can be ducted to the outside using either rigid or flexible ducting Ø 120 or 150 mm, the choice of which is left to the installer. When 120 mm ducting is to be used it will be necessary to install the reduction flange item A on the air outlet (fig. 5). · If the hood is supplied with the activated charcoal filters fitted, the filters should be removed (see paragraph on Maintenance). · Recirculation fitting · The filtered air is returned to the room through the two plastic side grills G on the lower chimney element I . · Connect the additional spigot P to the round fan outlet, pushing it downwards, and fit spigot R to additional spigot P in a similar manner (make sure that the two additional side recirculation spigots P1 are fitted to spigot R). Make sure that the height of the assembly R + P corresponds to the height of the chimney outlet. (fig. 6). · Fit the activated charcoal filters inside the canopy (see paragraph on Maintenance ). Do not fit the venting grilles until after the chimney has been installed. P1 Fig. 6 R P G A18 _714 _03 2 S 2 I G Fig. [. . . ] 9 A18_07 0-1 MID MAX 0-1 18 GB MAINTENANCE Regular maintenance and cleaning will ensure good performance and reliability, while extending the working life of the hood. Special attention should be paid to the grease filters and to the charcoal filters when the hood is used in the recirculation mode. Metal grease filters · Cleaning The metal grease filter should be cleaned every two months with normal usage and can be cleaned in a dishwasher or by hand using a mild detergent or liquid soap. · Replacement Remove the filters one at a time, pushing the handle towards the rear of the hood (fig. 10). When replacing, ensure that the handle faces outwards. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZHC96X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZHC96X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag