User manual ZILOG Z8 ENCORE NVDS OPERATION IN THE Z8 ENCORE AND Z8 ENCORE XP APPLICATION NOTE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZILOG Z8 ENCORE. We hope that this ZILOG Z8 ENCORE user guide will be useful to you.

Lastmanuals help download the user guide ZILOG Z8 ENCORE.


Mode d'emploi ZILOG Z8 ENCORE
Download

You may also download the following manuals related to this product:

   ZILOG Z8 ENCORE USING THE TIMER OF THE Z8 ENCORE AND Z8 ENCORE XP FAMILY APPLICATION NOTE (249 ko)

Manual abstract: user guide ZILOG Z8 ENCORENVDS OPERATION IN THE Z8 ENCORE AND Z8 ENCORE XP APPLICATION NOTE

Detailed instructions for use are in the User's Guide.

[. . . ] F083A series Part Selection Guide Table3. F082A series Part Selection Guide Table 4. F1680 series Part Selection Guide The NVDS is implemented by special purpose Zilog® software stored in areas of program memory not accessible to the user. These special-purpose routines use the flash memory to store and read the data. [. . . ] A maintenance operation (every 200 writes for the F0830, F083A and F1680 series / every 400 to 500 writes for the F082A series) is necessary which takes up to 58 ms (F0830, F083A and F1680 series) to 61 ms (F082A series) to complete. Slower system clock speeds result in proportionally higher execution times. NVDS byte writes to invalid addresses (those exceeding the NVDS array size) have no effect. Illegal write operations have a 2 µs (F082A series) to 7 µs execution time (F0830, F083A and F1680 series). VDD = 2. 7 to 3. 6V TA = - 40ºC to +105ºC Parameter NVDS Byte Read Time NVDS Byte Program Time Data Retention Endurance Min 71 126 10 100, 000 Typ Max 256 136 Units µs µs years Cycles Notes With system clock at 20 MHz With system clock at 20 MHz 25ºC Cumulative write cycles for entire memory Table 7. F0830 and F083A NVDS timing values AN031001-0710 Page 4 of 9 NVDS Operation in the Z8 Encore!® and Z8 Encore!XP® MCU's Application Note VDD = 2. 7 to 3. 6V TA = 0ºC to +70ºC TA = - 40ºC to +105ºC Parameter NVDS Byte Read Time NVDS Byte Program Time Data Retention Endurance Min 34 0. 171 20 50, 000 Typ Max 519 39. 7 Units µs ms years cycles Notes With system clock at 20 MHz With system clock at 20 MHz 25ºC Cumulative write cycles for entire memory Table 8. F1680 NVDS timing values NVDS Read Operation Steps in reading a byte from the NVDS array: 1. Push the address of the NVDS array to be read 2. Issue a CALL instruction to the address of the Byte-Read routine 3. Pop the address off the stack At the return from the sub-routine, the read byte resides in working register R0, and the read status byte resides in working register R1. The bit fields of this status byte are defined in Table 6 and Table 9. The read routine uses 9 bytes (F082A series) to 16 bytes (F0830, F083A and F1680 series) of stack space in addition to the 1 byte of address pushed by the user. Table 9. Read Status Byte (F0830, F083A and F1680 series) Because of the Flash memory architecture, NVDS reads exhibit a non-uniform execution time. A read operation takes 71 µs - 258 µs (F0830, F083A and F1680 series) or 44 µs - 489 µs (F082A series) for a system clock of 20 MHz. Slower system clock speeds result in proportionally higher execution times. NVDS byte reads from invalid addresses (those exceeding the NVDS array size) return 0xFF. Illegal read operations have an execution time of 2 µs (F082A series) to 6 µs (F0830, F0383A and F1680 series). The status byte returned by the NVDS read routine is 0x00 for successful read. If the status byte is non-zero, there is a corrupted value in the NVDS array at the location being read. In this case, the value returned in R0 is the byte most recently written to the array that does not have an error. AN031001-0710 Page 5 of 9 NVDS Operation in the Z8 Encore!® and Z8 Encore!XP® MCU's Application Note VDD = 2. 7 to 3. 6V TA = - 40ºC to +105ºC Parameter NVDS Byte Read Time NVDS Byte Program Time Data Retention Endurance Min 34 0. 171 100 160, 000 Typ Max 519 39. 7 Units µs ms years cycles Notes With system clock at 20 MHz With system clock at 20 MHz 25ºC Cumulative write cycles for entire memory Table 10. F082A NVDS timing values AN031001-0710 Page 6 of 9 NVDS Operation in the Z8 Encore!® and Z8 Encore! [. . . ] XP® MCU's Application Note Warning: DO NOT USE IN LIFE SUPPORT LIFE SUPPORT POLICY ZILOG'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF ZILOG CORPORATION. As used herein Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Document Disclaimer ©2010 by Zilog, Inc. Information in this publication concerning the devices, applications, or technology described is intended to suggest possible uses and may be superseded. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZILOG Z8 ENCORE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZILOG Z8 ENCORE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag