User manual ZILOG ZMOTION APPLICATION WALKTHROUGH NOTE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZILOG ZMOTION. We hope that this ZILOG ZMOTION user guide will be useful to you.

Lastmanuals help download the user guide ZILOG ZMOTION.


Mode d'emploi ZILOG ZMOTION
Download
Manual abstract: user guide ZILOG ZMOTIONAPPLICATION WALKTHROUGH NOTE

Detailed instructions for use are in the User's Guide.

[. . . ] Application Note ZMOTIONTM Detection Module Application Walkthrough AN030701-0810 Abstract This application note describes in detail the application code associated with the ZMOTION Detection Module and how it can be used for detection and control applications. The ZMOTION Detection Module can be used either in Hardware Mode or Serial Mode. In the Hardware Mode, you use the hardware circuit selection for sensitivity adjustments, delay time settings, ambient light settings, and Sleep Mode. In the Serial Mode, you can use the UART interface to fine-tune the ZMOTION Detection Module with advanced configuration settings. [. . . ] Finally, the program checks again the status of the cModule Status1 (cModuleStatus1) flag. · If the Mode Pir Stable (MOD_PIR_STABLE) is LOW, then the program checks the PIR sensor stability after power up. This state changes the time delay of changing the state from one state to another. This state is used to control and monitor the signal associated with the Light Gate pin. This state indicates how the ePIR engine detected the last motion-detected event. When the ZMOTION sets the Motion Detected bit in ePIRStatus0, it also sets this bit according to which detection engine registered the event. This state is used to configure the motion detection. If the received command is `R', then it is requesting for a Reset. If the receive command is `M', then it is requesting for make motion detection. This state is used to configure the direction of the motion to positive, negative, or disabled. Positive movement is requested when a "+" is received, negative movement is requested when a "-" is received, and disabled motion detection is requested when "A" is received. This state determines if the engine should accept signals from one or two ePIR sensor. If configured as single operation then only one sensor is used which is connected to ANA2. If it is configured as dual operation then ZMOTION will scan two sensors simultaneously with the second sensor connected to ANA3. This state changes the sensitivity of the ZMOTION. If this state is enabled, the engine considers smaller signal changes as valid motion events. This significantly increases sensitivity at the cost of more potential false motion detections. This state is used to clear and temporarily save the received command. This state determines the frequency response of the motion detection system. Higher values allow lower frequencies to be accepted by the ePIR engine. Lower values cause the engine to ignore targets that generate lower frequencies. This state determines the relative range of motion detection. [. . . ] ePIR Sensitivity Register (ePIR_Sensitivity Define ePIR_SENSITIVITY Value FFh Description (R/W) Register used to adjust the sensitivity of the ePIR Table 26. ePIR API Status/Control Register 0 (ePIR_SC0) Define SC0_PIR_STABLE SC0_MOTION_DETECTED SC0_MOTION_DIRECTION SC0_DIRECTION_CONTROL SC0_MD_SUSPEND SC0_ENGINE_DISABLED SC0_EXTENDED Value 01h 02h 04h 08h 10h 20h C0h Description (R) Status/Control Register 0 PIR Stable (R/W) Status/Control Register 0 Motion Detected (R) Status/Control Register 0 Motion Direction (R/W) Status/Control Register 0 Direction Control (R/W)Status/Control Register 0 Motion Detection Suspend (R) Status/Control Register 0 Engine Disabled (R/W) Status/Control Register 0 Extended Table 27. ePIR API Status/Control Register 1 (ePIR_SC1) Define SC1_DUAL_PYRO_ENABLE SC1_BIT1_RESERVED SC1_PIR_SCAN_RATE SC1_FREQUENCY_RESPONSE SC1_ENGINE_TIMER_TICK Value 01h 02h 04h 78h 80h Description (R/W) Status/Control Register 1 Dual Pyro Enable (R) Status/Control Register 1 Bit1 Reserved (R/W) Status/Control Register 1 PIR Scan Rate (R/W) Status/Control Register 1 Frequency Response (R/W) Status/Control Register 1 Engine Timer Tick AN030701-0810 Page 26 of 30 ZMOTIONTM Detection Module Application Walkthrough Table 28. ePIR API Status/Control Register 2 (ePIR_SC2) Define SC2_BIT34567_RESERVED SC2_RANGE_CONTROL Value F8h 07h Description (Reserve) Status/Control Register 2 Bit34567 Reserved (R/W) Status/Control Register 2 Range Control Table 29. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZILOG ZMOTION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZILOG ZMOTION will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag