User manual ZYXEL ES-2024A QUICK GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZYXEL ES-2024A. We hope that this ZYXEL ES-2024A user guide will be useful to you.

Lastmanuals help download the user guide ZYXEL ES-2024A.


Mode d'emploi ZYXEL ES-2024A
Download

You may also download the following manuals related to this product:

   ZYXEL ES-2024A (5023 ko)
   ZYXEL ES-2024A V3.70 (6516 ko)

Manual abstract: user guide ZYXEL ES-2024AQUICK GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] ES-2024A Ethernet Switch User's Guide Version 3. 60 6/2005 ES-2024A User's Guide Copyright Copyright © 2005 by ZyXEL Communications Corporation. The contents of this publication may not be reproduced in any part or as a whole, transcribed, stored in a retrieval system, translated into any language, or transmitted in any form or by any means, electronic, mechanical, magnetic, optical, chemical, photocopying, manual, or otherwise, without the prior written permission of ZyXEL Communications Corporation. Published by ZyXEL Communications Corporation. All rights reserved. Disclaimer ZyXEL does not assume any liability arising out of the application or use of any products, or software described herein. [. . . ] Click Apply to save the changes Click Cancel to start configuring the screen again. Apply Cancel 8. 6 Port-based VLAN Setup Port-based VLANs are VLANs where the packet forwarding decision is based on the destination MAC address and its associated port. Port-based VLANs require allowed outgoing ports to be defined for each port. Therefore, if you wish to allow two subscriber ports to talk to each other, for example, between conference rooms in a hotel, you must define the egress (an egress port is an outgoing port, that is, a port through which a data packet leaves) for both ports. Port-based VLANs are specific only to the switch on which they were created. Note: When you activate port-based VLAN, the switch uses a default VLAN ID of 1. In screens (such as IP Setup and Filtering) that require a VID, you must enter 1 as the VID. The port-based VLAN setup screen is shown next. The CPU management port forms a VLAN with all Ethernet ports. 8. 6. 1 Configure a Port-based VLAN Select Port Based as the VLAN Type in the Switch Setup screen (see Figure 31 on page 68) and then click VLAN from the navigation panel to display the next screen. 72 Chapter 8 VLAN ES-2024A User's Guide Figure 35 Port Based VLAN Setup (All Connected) Chapter 8 VLAN 73 ES-2024A User's Guide Figure 36 Port Based VLAN Setup (Port Isolation) The following table describes the labels in this screen. 74 Chapter 8 VLAN ES-2024A User's Guide Table 17 Port Based VLAN Setup LABEL Setting Wizard DESCRIPTION Choose All connected or Port isolation. All connected means all ports can communicate with each other, that is, there are no virtual LANs. All incoming and outgoing ports are selected. This option is the most flexible but also the least secure. Port isolation means that each port can only communicate with the CPU management port and cannot communicate with each other. All incoming ports are selected while only the CPU outgoing port is selected. This option is the most limiting but also the most secure. After you make your selection, click Apply (top right of screen) to display the screens as mentioned above. You can still customize these settings by adding/deleting incoming or outgoing ports, but you must also click Apply at the bottom of the screen. These are the ingress ports; an ingress port is an incoming port, that is, a port through which a data packet enters. If you wish to allow two subscriber ports to talk to each other, you must define the ingress port for both ports. The numbers in the top row denote the incoming port for the corresponding port listed on the left (its outgoing port). CPU refers to the switch management port. By default it forms a VLAN with all Ethernet ports. If it does not form a VLAN with a particular port then the switch cannot be managed from that port. [. . . ] The number of "borrowed" host ID bits determines the number of subnets you can have. The remaining number of host ID bits (after "borrowing") determines the number of hosts you can have on each subnet. Table 72 Subnet 1 NETWORK NUMBER IP Address IP Address (Binary) Subnet Mask Subnet Mask (Binary) Subnet Address: 192. 168. 1. 0 Broadcast Address: 192. 168. 1. 127 192. 168. 1. Lowest Host ID: 192. 168. 1. 1 Highest Host ID: 192. 168. 1. 126 LAST OCTET BIT VALUE 0 00000000 128 10000000 Table 73 Subnet 2 NETWORK NUMBER IP Address IP Address (Binary) Subnet Mask Subnet Mask (Binary) Subnet Address: 192. 168. 1. 128 Broadcast Address: 192. 168. 1. 255 192. 168. 1. Lowest Host ID: 192. 168. 1. 129 Highest Host ID: 192. 168. 1. 254 LAST OCTET BIT VALUE 128 10000000 128 10000000 The remaining 7 bits determine the number of hosts each subnet can have. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZYXEL ES-2024A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZYXEL ES-2024A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag