Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual 3COM AUI XCVR INTERFACE. We hope that this 3COM AUI XCVR INTERFACE user guide will be useful to you.
Lastmanuals help download the user guide 3COM AUI XCVR INTERFACE.
Manual abstract: user guide 3COM AUI XCVR INTERFACE
Detailed instructions for use are in the User's Guide.
[. . . ] Any replaced or repaired product or part has a ninety (90) day warranty or the remainder of the initial warranty period, whichever is longer. 3Com shall not be responsible for any software, firmware, information, or memory data of Customer contained in, stored on, or integrated with any products returned to 3Com pursuant to any warranty.
Figure 1
This manual provides a general description of the 3Com Female AUI Transceiver Module, 3C12060. Please retain this manual with your other 3Com manuals for future use.
SOFTWARE: 3Com warrants that the software programs licensed from it will perform in substantial conformance to the program specifications therefor for a period of ninety (90) days from the date of purchase from 3Com or its Authorized Reseller. 3Com warrants the magnetic media containing software against failure during the warranty period. [. . . ] Nothing in this warranty shall be taken to affect your statutory rights.
The 3Com® Female AUI Transceiver Module has been designed to the IEEE 802. 3 specification for an AUI interface to provide external transceiver connectivity. The Transceiver Module provides an extra port or connectivity to another medium on the following LinkBuilder® products: · ECS modules (3C12076 and 3C12050/1) · MSH modules (3C18110, 3C18120, 3C18124, 3C18146 and 3C18600) · FMS Stackable Hubs (3C16250, 3C16265, 3C16271 and 3C16371) · FMS II Stackable Hubs (3C16665, 3C16670 and 3C16671) · Repeaters (3C16170, 3C16200, 3C16210 and 3C16505) This product has the benefit of a "lifetime warranty": see page 4. 2 Installation
The Transceiver Module provides a 15-pin female AUI connector (acting as a DTE port) at the external interface end. A 16-pin header and a 16-way edge connector are mounted at the other end of the Transceiver Module for connection to a Module, Stackable Hub or Repeater. The Transceiver Module is connected to an external transceiver directly or with an AUI cable (transceiver cable or drop cable) with a maximum length of 50 metres (although in most cases 3 metres should be sufficient). The Transceiver Module will enable the Module, Stackable Hub or Repeater to connect to a variety of transmission medium such as a fiber, UTP, STP or Thin Ethernet. Example
Stackable Hub
GOVERNING LAW:
This Limited Warranty shall be governed by the laws of England.
3Com Limited, ISOLAN House, Brindley Way, London Road, Hemel Hempstead, Hertfordshire, HP3 9XJ, UK. 44(0)442 278000 23/12/93
!
Only qualified personnel should install this device. Use an earthed wrist-band!
Female AUI Transceiver Module
up to 50 m AUI Cable
External Transceiver
Thin Ethernet Segment
Page 4
Page 1
Preparation Before you install the Transceiver Module, you must remove the Module, Hub or Repeater from the network and all power sources. Modules must be removed from the Chassis (you do not need to power down the Chassis first). The 3C18146 Expansion Module must be separated from its mother module. See the relevant User Guide or `How to Install and Use. . . ' manual. Remove the blanking plate from the unit in which you are going to install the Transceiver Module. The relevant manual will tell you where to find the plate. Keep the blanking plate in a safe place so that it can be replaced when the Transceiver Module is removed. Installing in a Stackable Hub or Repeater For FMS Stackables and Repeaters, hold the mounting panel with the pin header side of the board down. For FMS II Stackables, hold the mounting panel with the pin header side of the board up. Insert the edge connector end of the Transceiver Module into the rear of the mother device. Slide the Transceiver Module in carefully to engage in the slot and push it fully home. Fix the mounting panel of the Transceiver Module to the back panel using the two screws from the blanking plate. [. . . ] Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur : "Appareils Numériques", NMB-003 édictée par le ministre des Communications.
Re-install the mother device into its chassis and/or network and power up. The Transceiver Module will operate correctly once power is applied. 4 Problems Disclaimer
Information in this document is subject to change without notice and does not represent a commitment on the part of 3Com. 3Com reserves the right to revise or change this document without obligation of 3Com to notify any person of the revisions or changes. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE 3COM AUI XCVR INTERFACE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual 3COM AUI XCVR INTERFACE will begin.