User manual 3M 8560 3C CABLE BREAKOUT BOOTSRJS 3C PHASE REJACKETING

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual 3M 8560 3C CABLE BREAKOUT BOOTSRJS 3C PHASE REJACKETING. We hope that this 3M 8560 3C CABLE BREAKOUT BOOTSRJS 3C PHASE REJACKETING user guide will be useful to you.

Lastmanuals help download the user guide 3M 8560 3C CABLE BREAKOUT BOOTSRJS 3C PHASE REJACKETING.


Mode d'emploi 3M 8560 3C CABLE BREAKOUT BOOTSRJS 3C PHASE REJACKETING
Download
Manual abstract: user guide 3M 8560 3C CABLE BREAKOUT BOOTSRJS 3C PHASE REJACKETING

Detailed instructions for use are in the User's Guide.

[. . . ] 3 Cold Shrink- Silicone Rubber 8560 Series 3/C Cable Breakout Boots RJS Series 3/C Phase Rejacketing System 3 Conductor Cable 3MTM Cold Shrink Silicone Rubber 8560 Series 3/C Cable Breakout Boots and 3MTM Silicone Rubber RJS Series 3/C Phase Rejacketing System are designed to be used in conjunction with three 3M terminations, to seal the breakout area and rejacket the phases on three conductor cable. Innovations in molded silicone rubber technology, now make possible a complete three conductor all silicone termination. The termination itself can be made with 3MTM Cold Shrink QT-III Indoor and Outdoor Silicone rubber termination. [. . . ] 8560 Series Breakout Boots can be used in conjunction with 3M Silicone Rubber Cold Shrink Rejacketing Sleeves for 3/C shielded power cable terminating applications. Features and Benefits: · Versatile; installs quickly and accommodates a wide range of cable sizes. · Simple hand application; no need for special installation tools. · No specific user skills or craftsmanship required. · Excellent resistance to ozone and ultra-violet radiation · Good solvent resistance; compatible with industry ­ approved cable cleaners. · High dry and wet insulation resistance. · Highly flexible; accommodates all power cable supplier bend radius recommendations. · Seals tight; retains resiliency and pressure even after prolonged years of aging and exposure. · Compatible with all 3M Cold Shrink Termination Products and RJS Series Phase Rejacketing Sleeves. Rejacketing Sleeve 3MTM 3/C Phase Rejacketing System 3M RJS Series Rejacketing Sleeves are designed so that 3M Cold Shrink QTII & QTIII Silicone Rubber Terminations can be used on 3/C (three conductor) medium voltage shielded power cables of tape shield, wire shield, armored and non-armored configurations. RJS Rejacketing Assemblies are a series of silicone rubber insulators incorporating an inner-expandable polyester braid designed to reduce sliding friction and deliver the insulator onto the cable. Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments. Rejacketing sleeves are designed to be used in conjunction with 3M Cold Shrink Breakout Boots and Silicone Rubber Terminations. Features and Benefits: · Versatile; installs quickly and accommodates a wide range of cable sizes. · Simple hand application; no need for special installation tools. · No specific user skills or craftsmanship required. · Excellent resistance to ozone and ultra-violet radiation · Good solvent resistance; compatible with industry ­ approved cable cleaners. [. . . ] SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY INJURY OR FOR ANY DIRECT OR CONSEQUENTIAL DAMAGES SUSTAINED OR INCURRED BY REASON OF THE USE OF ANY OF THE SELLER'S PRODUCTS THAT WERE DEFECTIVE. 3 Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 800/245 3573 http://www. 3M. com/elpd Litho in USA. 40% Pre-consumer waste paper 10% Post-consumer waste paper © 3M 1998 80-6109-4259-3 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE 3M 8560 3C CABLE BREAKOUT BOOTSRJS 3C PHASE REJACKETING

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual 3M 8560 3C CABLE BREAKOUT BOOTSRJS 3C PHASE REJACKETING will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag