User manual 3M BENCHTOP AIR IONIZER 963 BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual 3M BENCHTOP AIR IONIZER 963 BROCHURE. We hope that this 3M BENCHTOP AIR IONIZER 963 BROCHURE user guide will be useful to you.

Lastmanuals help download the user guide 3M BENCHTOP AIR IONIZER 963 BROCHURE.


Mode d'emploi 3M BENCHTOP AIR IONIZER 963 BROCHURE
Download
Manual abstract: user guide 3M BENCHTOP AIR IONIZER 963 BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] 963/963E Benchtop Air Ionizers Rapid neutralization of electrostatic charge The ion-generation technology present in the 963 and 963E benchtop air ionizers is capable of producing extremely large amounts of ions, resulting in nearly instantaneous static charge neutralization. The 3M 963 is capable of reducing a static charge of 1000V to 100V in less than one second, at a one foot distance, when tested* at the high fan speed. In addition, the powerful fan allows the generated ions to be carried at high speed for long distances. [. . . ] Where industrial noise may irritate personnel and lower productivity, the 963 and 963E may be used without contributing significantly to the ambient noise. The fan's gentle airflow does not disturb paper or delicate parts. The high-speed fan setting can be used for more rapid neutralization of static charges in environments where faster decay rates are required. Static-dissipative housing safe to use in ESD sensitive areas The injection-molded plastic case is constructed of static-dissipative plastic. The conductivity of the case prevents a static charge from building up on the surface of the housing, a common problem with ionizers. This "ESD-safe" design allows the ionizer to be part of your overall static-safeguarded electronic workstation. * 1 The use of ionized air in electronics work environments eliminates the build up of potentially damaging static charges. Air ionizers are primarily used to control static charge on nonconductive materials. Grounding is normally used to control charge on conductive objects and personnel, however, nonconductors cannot be grounded to drain electrostatic charge. Ionization is the only method of neutralizing a static charge on a nonconductor. Ionized air can neutralize static charges on circuit board substrates, insulating tapes and plastic objects found in the work area. The 3MTM 963 and 963E benchtop air ionizers, blanket the benchtop with ionized air to help prevent static from damaging sensitive electronics. Two versions of Benchtop Air Ionizer available The 963 benchtop air ionizer uses AC 120V power, while the 963E uses AC 220V/230V power. Both ionizers feature a two-speed fan, a power indicator lamp, a static-dissipative plastic housing, and a combination metal-plastic stand that can also double as a mounting bracket. When tested according to ANSI/ESD S3. 1-1991 Meets Global Regulatory Requirements Global usage of electronic products are often dependent on the product meeting regulatory requirements for the country of usage. To achieve this end, the 3MTM Models 963 and 963E have been tested to, and have passed, regulatory testing for U. S. , Canada, Mexico and the European Union. [. . . ] SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY INJURY OR FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES SUSTAINED OR INCURRED BY REASON OF THE USE OF ANY OF THE SELLER'S PRODUCTS. Electronic Handling & Protection Division 6801 River Place Blvd. Austin, TX 78726-9000 www. 3M. com/ehpd Recycled paper 40% Pre-consumer waste paper 10% Post-consumer waste paper Litho in USA. © 3M 1999 98-0799-0457-3 (6910. 0)JHA/WP [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE 3M BENCHTOP AIR IONIZER 963 BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual 3M BENCHTOP AIR IONIZER 963 BROCHURE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag