User manual ABIT SL6

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ABIT SL6. We hope that this ABIT SL6 user guide will be useful to you.

Lastmanuals help download the user guide ABIT SL6.


Mode d'emploi ABIT SL6
Download
Manual abstract: user guide ABIT SL6

Detailed instructions for use are in the User's Guide.

[. . . ] Copyright and Warranty Notice The information in this document is subject to change without notice and does not represent a commitment on part of the vendor, who assumes no liability or responsibility for any errors that may appear in this manual. No warranty or representation, either expressed or implied, is made with respect to the quality, accuracy or fitness for any particular part of this document. In no event shall the manufacturer be liable for direct, indirect, special, incidental or consequential damages arising from any defect or error in this manual or product. Product names appearing in this manual are for identification purpose only and trademarks and product names or brand names appearing in this document are the property of their respective owners. [. . . ] ECP Mode Use DMA: Two options are available: 1 ) 3. When the mode selected for the parallel port mode is ECP, the DMA channel selected can be Channel 1 or Channel 3. PWRON After PWR-Fail: This setting lets you set the system action after a power failure. Three options are available: On ) Former-Sts ) Off. The default setting is Off. Game Port Address: Three options are available: Disabled ) 201 ) 209. This item sets the address of the onboard game port connector. Midi Port Address: Four options are available: Disabled ) 330 ) 300 ) 290. This item sets the address of the onboard midi port connector. SL6 BIOS Setup 3-31 Midi Port IRQ: Two options are available: 5 ) 10. This item sets the IRQ of the onboard midi port connector. If you choose disable the Midi Port Address, then this field is not available. Note If you buy the audio adapter and want to replace the use of onboard audio solution, you have to disable three items in BIOS. Otherwise, your audio adapter may not work well. These three items are: AC 97 Audio set to Disabled Game Port Address set to Disabled Midi Port Address set to Disabled User's Manual 3-32 Chapter3 3-6. Power Management Setup Menu The difference between Green PCs and traditional computers is that Green PCs have a power management feature. With this feature, when the computer is powered on but inactive, the power consumption is reduced in order to save energy. When the computer operates normally, it is in Normal mode. In this mode, the Power Management Program will control the access to video, parallel ports, serial ports and drives, and the operating status of the keyboard, mouse and other device. These are referred to as Power Management Events. In cases where none of these events occur, the system enters the power saving mode. When one of the controlled events occurs, the system immediately returns to normal mode and operates at its maximum speed. Power saving modes can be divided into three modes according to their power consumption: Doze Mode, Standby Mode, and Suspend Mode. The four modes proceed in the following sequence: Normal Mode ===> Doze Mode ===> Standby Mode ===> Suspend Mode The system consumption is reduced according the following sequence: Normal > Doze > Standby > Suspend 1. In the Main Menu, select "Power Management Setup" and press "Enter". The following screen is displayed: SL6 BIOS Setup 3-33 Figure 3-7A. [. . . ] How they serve you is also a good reference for your next purchase. If you feel that you need to contact ABIT directly you can send email to the ABIT technical support department. First, please contact the support team for the branch office closest to you. They will be more familiar with local conditions and problems and will have better insight as to which resellers offer what products and services. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ABIT SL6

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ABIT SL6 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag