User manual ACER ALTOS RS700 INSTALLATION GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ACER ALTOS RS700. We hope that this ACER ALTOS RS700 user guide will be useful to you.

Lastmanuals help download the user guide ACER ALTOS RS700.


Mode d'emploi ACER ALTOS RS700
Download
Manual abstract: user guide ACER ALTOS RS700INSTALLATION GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] AcerAltos RS700 Enclosure Installation Guide Copyright Copyright © 1998 by this company. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of this company. Disclaimer This company makes no representations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties, merchantability or fitness for any particular purpose. Any software described in this manual is sold or licensed "as is". Should the programs prove defective following their purchase, the buyer (and not this company, its distributor, or its dealer) assumes the entire cost of all necessary servicing, repair, and any incidental or consequential damages resulting from any defect in the software. [. . . ] MSCS (Microsoft Cluster Server) clustering provides three main benefits: 1. Single device failure will not cause the service stopped. Fa il O Server 3 ve r Server 3 Network Network Server 1 Server 2 Server 1 Server 2 Server 1 High Availability Scalability 2. Scalability. server. Add more servers to increase the capacity of the cluster 24 3. Centralized administration. The administration of applications and services is centralized through the use of CLUSTER ADMINISTRATOR. Cluster solution for AcerAltos Server You can use the two AcerAltos servers, one hub and the cluster cable kits of Acer's cluster to build up the cluster environment, and then setup the MSCS by using the Microsoft Windows NT server 4. 0, Enterprise Edition. . . . . . . . . . . . . . . . . . . . . . . . . Public Network Node 1 Node 2 Private Net Shared SCSI Bus Cluster 25 Acer's Cluster Solution Solutions 1. Two-node Cluster that comply with MSCS (Microsoft Cluster Server). Two AcerAltos Servers + AcerAltos RS700 RAID Storage. AcerAltos 3102RS RAID Box supporting three Ultra SCSI Channels: One for host channel, and two for drive channels. Built-in SCSI Expander on RS700 RAID storage. 4. Support up to two AcerAltos RS700 RAID storage units. The cabling length of the SCSI host bus can be up to 12 meters. Acer's Cluster Server 26 SCSI Expander 27 The Architecture of Acer's Cluster Server Hub Public Network Private Network AcerAltos Server BPB External LVD Cable CH0 3102RS RAID Box CH1 BPB CH2 68-pin Ultra SCSI SCSI Expander Card AcerAltos RS700 Ultra2 SCSI Card 28 Two-node Cluster Cable Kits for Rackmount or StandAlone Cluster Cable kit for RackMount Includes the following items: 1. External Ultra2 SCSI Cable (2500mm) * 1 STP Cross-Over Cable * 1 (for private network) Cluster Cable kit for Stand-Alone It includes the following items: 1. External Ultra2 SCSI Cable (1000mm) * 1 STP Cross-Over Cable * 1 (for private network) 29 System Requirements Hardware Requirements: · · · · · · AcerAltos Server * 2 (w/I two SCSI channels and two NICs) AcerAltos RS700 RAID Storage * 1 One Network Hub + LAN Cables Two-node Cluster Cable Kit Software Requirements: Microsoft Windows NT server 4. 0, Enterprise Edition Other Applications (Optional) (i. e. , SQL Server, Exchange Server, etc. ) 30 Hardware Installation and Configuration Hardware Installation 1. Ensure that you have got the all of the hardware requirements of Acer's cluster server, and refer to the architecture of Acer's Cluster to build up the cluster. Connect the private network between two nodes by using the STP crossover cable. You must insert another NIC on each node and connect them to the Public Network (Hub). Connect the External SCSI Cables between two Hosts and the AcerAltos RS700. 2. 3. 4. Hardware Configuration 1. Host configuration a) Power on each AcerAltos Server and press <Ctrl>+<A> for the SCSISelectTM Utility when the screen shows this message: "Adaptec AIC-7880 Ultra/Ultra W BIOS V 1. x". Click the "Configure/View Host Adapter Setting" and choose the SCSI channel 1(which connects to the AcerAltos RS700). Enable the Host Adapter SCSI Termination function. Enable the Multiple LUN Support function in the Advanced Configuration options. Set the host's SCSI ID to 6 for SCSI channel 1 of Host 1. Set the host's SCSI ID to 7 for SCSI channel 1 of Host 2. b) c) d) e) 31 2. Configuring the RAID Box. It is very important to configure the RAID Box to create Acer's cluster server. [. . . ] The overall features of a fully-built RAID system will, however, depend on the actual components used and the creativity of the integrator. Basic Features · Five operating modes: · · · · · Non-RAID RAID-0 RAID-1 RAID-3 RAID-5 Disk-spanning Disk striping Disk mirroring and striping (RAID 0+1) Disk striping with dedicated parity Multiple block striping with interspersed parity 59 · Comprehensive failure management including: · · · · · Automatic bad sector reassignment Hot-swapping Spare drive operation (supports both global spare and local spare) Background rebuilding (rebuild priority selectable) Verify-after-write supported on normal writes, rebuild writes and/or RAID initialization writes · · · · · · · · · · · · · · · Works with any operating systems without additional software drivers 5. 25" drive profile allows easy integration into external subsystem enclosures directly into the host system's drive bay Up to five drive channels (optional 3-channel upgrade) for a total of 75 connected drives Supports up to 15 SCSI IDs per channel Up to 8 logical drives, each with independent RAID modules Up to 8 partitions per logical drive Dynamic mapping of LUNs to logical drives. Two or more LUNs can be mapped to the same logical drive for redundant host operation Performance optimization for Sequential or Random I/O Allows multiple drive failure and concurrent multiple drive rebuild of a RAID (0+1) logical drive Two or more SCSI channels can be simultaneously set as host interface for redundant host system operation EDO DRAM supported for enhanced performance Up to 128 Mbytes of intelligent Read-Ahead/Write-Back cache with optional battery backup Optional battery backup module to protect data in Write-Back cache when a power failure occurs Front panel LCD and push buttons for configuration and message display Acer RAID Manager and RS-232 terminal interface for RAID management 60 · Supports Fault-bus for enclosure management Channel Connection Setup Table Channel # CH0 Host/Drive Channel Host ID# 0 Terminator On Connection Connect to the SCSI expansion slots and ready to connection with the host server Connect to the first 3 drive trays Connect to the last 4 drive trays CH1 CH2 Drive Drive 7 7 On On 61 Appendix B SCSI Expander SCSI Expander (EP-SL) Single-ended and Low Voltage Differential signals are incompatible at the electrical level: however, you can use a converter to change the signals. The SCSI Expander is an extension and a converter card for SCSI devices. It converts Single-Ended (SE) electrical signal type to Low Voltage Differential (LVD) electrical signal type extending the limited cable length of SE signals. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACER ALTOS RS700

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ACER ALTOS RS700 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag