Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ACT ACT ENTRY A10. We hope that this ACT ACT ENTRY A10 user guide will be useful to you.
Lastmanuals help download the user guide ACT ACT ENTRY A10.
Detailed instructions for use are in the User's Guide.
[. . . ] Exit Programming Mode On the digital keypad press button . The ACTentry A10 is now ready for normal use. Note: The ACTentry A10 may be returned to its factory default condition at any time by entering the programming mode and pressing button three times.
For Door 2 Operation
1. Change User 2 Code On the digital keypad: Press Button 0, then Press Button 2 (for User 2). [. . . ] (e. g -9999-1-1-0- ) To set user 2 to open Door 2: Enter 1(set outputs), followed by 2(user2), followed by 2 (Door 2 timed) (e. g. -9999-1-2-2- )
Setting timers:
(From programming mode) Enter 2 (Set Timers 0-4 (Timer number) {Buzzer sounds indicating timing. . . wait required period} (Stop timing) {Buzzer stops timer set}
6
ACTentry A10 Operating and Installation Instructions
Timer No. 0 1 2 3 4
Function Relay time Door 2 / Output 2 time Output 3 time Door Ajar time Guest Buzzer time
Default 5s 5s 5s 30s 2s
Timers may be set to any duration between 2 seconds and 4 minutes.
Setting Configuration:
(From programming mode) Enter 30-37 or 40-47 0-1 (Option number) (1= Set, 0 = Unset)
Option
30 31 32 33
Function
Door Chime
Default
Off Off On Off
Operation
When set, whenever the door contact is opened, the built-in buzzer makes a chime sound and the buzzer output activates for 2 seconds. When set, the keypad operates silently, that is no audible tones (key-presses or confirm tones) are produced from the built-in buzzer function (function 0). When set (default), the keypad illumination is always on. This option will override option 42 (Auto backlighting) When set, and when the relay is active (following a valid code or buttonr elease), the relay timer is truncated to 2 seconds when the door contact opens. This ensures that irrespective of programmed relay time, the door will be locked as soon as it closes, and any person following will have to enter a code. When set, the keypad may be used as a remote keypad for an alarm system. The red and green indicators are controlled by the door contact and the release button inputs inputs respectively, and the built in buzzer is controlled by the interlock input. When set, two or more keypads may be interlocked so that only one controlled door may be open at any one time. The interlock output is active whenever the relay is active or when the door contact is open. When the interlock input is active the release button and all codes are inactive, and the red indicator flashes. The interlock outputs and inputs of any number of keypads may be combined on a single wire. When set, all user codes, and the programming code, are six digits long. The default user one code becomes 123456 and the default programmer code becomes 999999. When set, two different codes must be entered within 15 seconds in order to open the door. The outputs activated are those which have been programmed for the first code to be entered.
Silent Operation Permanent Backlighting Locksaver (Anti Tailgating)
34
Alarm Keypad Operation Interlock
Off
35
Off
36
Six Digit Codes Codes Twin Codes
Off
37
Off
7
ACTentry A10 Operating and Installation Instructions Option
40
Function
Door Forced Alarm Group Disable
Default
Off
Operation
When set, the buzzer output is activated, if the door contact opens when a valid code has not been entered. The output is deactivated when a valid code is next entered. This is useful for monitoring fire doors etc. When set, the top five user codes (5-9) are inactive any time the interlock input is activated. This restricts access to certain codes under external control (i. e. [. . . ] Remove power again Restore power and proceed with programming.
Note: The keypad will not operate correctly without LK1 in place.
8
ACTentry A10 Operating and Installation Instructions
Troubleshooting
We have identified a number of issues that may occur during or after installation that may reduce the quality of the ACTentry A10 operation. If you do not feel your system is working at an optimum level please review the following prior to contacting our Technical Support Helpdesk. Low Volume through the Speaker Grill on the Door Entry Panel Please check the following: 1. Adjust the Volume from the Speech Unit by adjusting control A. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ACT ENTRY A10
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT ACT ENTRY A10 will begin.