ACT ACT 5 INSTALLATION (359 ko)
Manual abstract: user guide ACT ACT 5DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] ACT 5 & ACT 5prox Digital & Proximity Keypads
The ACT 5 and the ACT 5prox are simple to use and easy to install standalone access control products. [. . . ] The ACT 5 and the ACT 5prox may be surface or flush mounted on to a standard single gang electrical back box.
ACT 5 Digital Keypad Main Features · · · · 10 User Codes Keypad Backlighting Incorrect code lockout 5 amp door relay output
ACT 5 Digital Keypad
ACT 5prox Digital Keypad & Proximity
ACT 5prox Digital Keypad and Proximity Main Features · 50 Users with unique Pin Codes and / or ACTProx Cards. Operating modes are Proximity, PIN and Proximity or PIN only. Keypad Backlighting Incorrect code lockout 5 amp door relay output Users can be deleted if a card is lost or a Pin Code forgotten
220/240 Volts AC
· · · ·
Installation Guidelines · · · · · 12 to 24 volts AC or DC supply required 5 amp lock output Can be installed either indoors or outdoors (IP67) Operating Temperture: -10 to +50 C Can be surface or flush mounted
PSU
12/24 Volts AC/DC
EXIT
ACT 5 and ACT 5prox System Schematic
Digital Proximity Keypads ACT 5 & ACT 5prox Digital &&Proximity Keypads
Ordering Information
Digital Keypad Proximity and Digital Keypad Proximity Card Proximity Fob Proximity Half Shell Card ACT5 ACT5prox ACTProx ISO-B ACTProx Fob-B ACTProx HS-B
Proximity & Magnetic Stripe Card ACTProx DUO-B
ACT 5 Digital Keypad ACT 5prox Digital Keypad & Proximity
Accessories
ACT Standalone Products Comparison Chart
PRODUCT FEATURES Doors 1 10 1 50 2 10 2 ACT 5 ACT 5prox ACT 10 ACT Smart2 1070 1 1000 1 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 5 amp Yes 5 amp Yes 5 amp 2 2 2 Yes Yes Yes Yes Yes IP67 Yes IP67 Yes IP54 Yes Yes Yes IP67 2 Yes Yes Yes IP67 2 Yes Yes Yes IP67 Yes 5 amp 1 Yes Yes Yes Yes Yes 5 amp 1 Yes Yes Yes Yes Yes 5 amp 1 Yes Yes Yes ACT Smart2 1080 1 1000 1 Yes Yes Yes Yes Yes Yes Yes ACT Smart2 1090 1 1000 1 Yes
ACT 5 and ACT 5prox
Users User Groups Master Slave Operation Proximity Pin Only Pin & Proximity Pin or Proximity
Flush Mount Plate
Surface Mount Collar
Proximity Only Keypad Backlighting Interlock Door Monitoring Fire Alarm Override
ACT 5prox Fobs and Cards
Master Slave Operation Toggle Mode Door Relay Output Programmable Imputs Programmable Outputs Programmable Inputs/ Outputs Push to release button input
ACTProx Fob-B
Robust proximity fob with a max read range of 6cm
ACTProx ISO-B
Suitable for ID printing with a maximum read range of 8 centimeters
Tamper Output 12-24volt DC or AC Input* IP Rating
* ACTSmart2 units require a DC supply when programmable input / outputs or master slave operation are used.
Product Specification
ACT 5 Number of Users 10 PIN Codes 12 to 24 Volts AC or DC 30mA (nominal), 120 mA (maximum) -10 to +50 degrees C 0 - 255 seconds 5A / 250 Vac 200 grams Flush Mount: 100 x 110 x 35 (mm) Surface Mount: 100 x 110 x 35 (mm) Surface or Flush Indoor or outdoor (IP67 rating) Rugged Polycarbonate housing, stainless steel keys, potted electronics ACT 5prox 50 (50 unique PINs and 50 Cards) 12 to 24 Volts AC or DC (linear PSU) 60mA (nominal), 100mA (maximum) -10 to +50 degrees C 0 255 seconds 5A / 250 Vac 200 grams Flush Mount: 100 x 110 x 20 (mm) Surface Mount: 100 x 110 x 35 (mm) Surface or Flush Indoor or outdoor (IP67 rating) Rugged Polycarbonate housing, stainless steel keys, potted electronics
ACTProx HS-B
Half shell card with a maximum read range of 8 centimeters
ACTProx DUO-B
Prox & mag stripe with max read range of 8 centimeters. Suitable for ID printing.
Operating Voltage Current Consumption Operating Temperature Door Open Time Relay Contact Rating Controller Weight
Access Control Technology
Unit C1, South City Bus Pk, Tallaght, Dublin 24, Ireland. [. . . ] w: www. accesscontrol. ie
Controller Size (H x W x D) Mounting Installation Construction [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ACT 5
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.