[. . . ] [. . . ] In turn up to 128 ACTpro 3000s may be networked via a PC interface to facilitate up to 2000 doors. The ACTpro 3000 can be configured and be maintained standalone or through ACTWin pro PC software. The ACTpro 3000 may be networked via RS485 or the built in TCP/IP capability.
Main Features
2 door controller expandable to 16 doors via a network of ACTpro 100/200 door expanders The ACTpro 3000 may be in turn networked with other ACTpro 3000s to create a network of up to 2000 doors Built in TCP/IP 10 Base-T Ethernet RS485 output to network ACTpro 100/200 door expanders RS485 input to network with other ACTpro 3000s 30, 000 users 1000 user groups 256 time zones Flash upgradeable firmware Timed anti passback Entry and exit reader support DDA individual timer facility
Client LAN / Ethernet
ACTpro 3000
Installation / Specification Guidelines
3000
The ACTpro 3000 requires a 12 volt dc supply The controller may not be installed outdoors unless it is in a sealed and heated cabinet The ACTpro 3000 is expanded from 2 to 16 doors via single door ACTpro 100/200 expanders The ACTpro 3000 controller may be networked via RS485 to expand the system up to 2000 doors maximum The maximum amount of ACTpro 3000s per RS485 output is 32 (ACT supply a 4x485 or 1x485 interface for PC networks) The ACTpro 3000 is compatible with ACTWin pro and ACTWin pro Lite software packages The ACTpro 3000 will operate standalone or can be connected to a PC For comparisons to our other controllers please check the comparison chart on the back page
Server
3000
3000
3000
100 100
100
200
200
200
IOM
8 8
IOM
8 8
ACTpro 1000/2000/3000 Controllers and ACTpro 100 expander require a 12 volts DC supply
ACTpro 3000 System Schematic
ACTpro 3000
Product Specification
Card access door controller
Operating Voltage: Current Consumption: Weight: Operating Temperature: Dimensions (HxWxD): Mounting: Installation:
12 Volts DC 210/400 mA 700 grams 0 to +50 C 270 x 190 x 60 mm Surface Indoor
ACT3000 Controller
Cabling Chart
From
Reader
ACTpro products comparison chart
Cable
8 core screen Twisted screen pair or Cat 5 Twisted screen pair or Cat 5 Twisted screen pair or Cat 5 Cable supplied
To
Controller
Restriction
30m at 5volts 100m at 12volts Maximum 1. 4km
Feature Doors Users User Groups Time Zones Event Log Anti passback Timed anti passback Entry and exit reader support Timed actions Interlock
ACTpro 1000 1 10, 000 16 16 500
ACTpro 2000 2 20, 000 1000 128 5000 Yes
ACTpro 3000 2 30, 000 1000 256 5000 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 5 amp 1 amp 2 (100 mA) 2 (100 mA) Yes 2, 000 max Yes Yes Yes 10 Base-T (RJ45)
ACTpro 100/200
ACTpro 2000
ACTpro 3000
PC Direct RS232
Maximum 30m
Yes Yes Yes
Yes Yes Yes Yes Yes
ACTpro 3000
Network RS485 interface PC
Maximum 1. 4km
Intruder Alarm System Integration User tracking Clock & Data or Wiegand auto detect Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 5 amp 2 (100 mA) 2 (100 mA) Yes 256 max Yes Yes Card only operation Card or pin Card and pin Auxiliary door operation Door monitoring Door control DDA extended timer facility Backlight Automatic daylight saving adjustment Fire alarm override Toggle mode Door relay output Auxiliary relay output Programmable inputs Programmable outputs Tamper & low voltage output Network doors Modem connection Built in TCP/IP TCP/IP compatible Ethernet Network Interface
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 5 amp 1 amp 2 (100 mA) 2 (100 mA) Yes 2, 000 max Yes Yes
Network RS485 interface
Maximum 30m
Ordering Information
Controller Door Expander I/O Module Single channel RS485 interface Four channel interface Lantronix 56k modem ACTpro 3000 ACTpro 100/200 ACTpro IOM ACT Net IF-1 (requires 12vdc supply) ACT Net IF-4 (Built in PSU) ACT LAN ACT 56K Modem
ACT LAN
ACTpro IOM
ACTpro 200 ACTpro 100 2 Door Expander Door Expander
56k Modem
4 channel RS485 Interface
Single channel RS485 Interface
Access Control Technology Unit C1, South City Business Park, Tallaght, Dublin 24, Ireland. [. . . ] [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ACTPRO 3000
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT ACTPRO 3000 will begin.