[. . . ] ACTpro200 Installation
2 Door Controller and Monitored Power Supply
WARNING: MAINS VOLTAGE DISCONNECT BEFORE MAINTENANCE
LED Functionality: Red LED indicates the status of communications with the controller. [. . . ] red lead connects to + terminal of battery black lead connects to - terminal of battery.
Door Address
4 5 6 7 8
+12V
RED
12V 0V
+5V
12V
0V
NC C NO NC C NO
GREEN
CLOCK
SENSE
0V
Max length: 30m from +5V 100m from +12V Battery 2 - Backup for Output 2 Monitoring for battery 2 can be disabled by setting dipswitch 3 to ON
Important !Always Place Varistor Across Lock Terminals
03 OFF OFF OFF ON 04 OFF OFF ON 05 OFF OFF ON 06 OFF OFF ON 07 OFF OFF ON 08 OFF ON 09 OFF ON 10 OFF ON 11 OFF ON 12 OFF ON 13 OFF ON 14 OFF ON 15 OFF ON 16 ON
ON
FACTORY DEFAULT This unit should be reset to its factory default condition before installation. To do this, power the unit up with ALL switches in the OFF position. The two LED's will illuminate for about 2 sec. The correct switch settings may then be set.
OFF OFF OFF ON ON ON OFF ON
This illustration shows wiring for a normally energised lock. If a normally de-energised lock is required, use the N/O relay contacts.
Technical Specifications
Mains Voltage Frequency Mains Fuse Secondary AC Fuse Fuse OP1 Fuse OP2 Ripple Voltage 230Vac +10% -15% 47-63 Hz 630mAmp 3. 15Amps 1. 25 Amps Quick 1. 25 Amps Quick <200mV
White Green Blue Red Black Brown Yellow Orange
SENSE CLOCK / DATA 1 DATA / DATA 0 +5V or +12V 0V RED GREEN (Buzzer Control)
OFF OFF OFF OFF OFF ON OFF ON OFF ON ON ON ON ON OFF ON
For Clock and Data Readers, wire exit reader in parallel but do not connect to SENSE. [. . . ] When the dipswitch is set to 4, Door 1 is set to Address 4 and Door 2 is set to Address 5.
ACTWinPro users must tick Mains Fault Reporting in the door view
www. accesscontrol. ie
Access Control Technology, Ireland. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ACTPRO200
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.