User manual ACT SMART2 PRODUCT RANGE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ACT SMART2 PRODUCT RANGE. We hope that this ACT SMART2 PRODUCT RANGE user guide will be useful to you.

Lastmanuals help download the user guide ACT SMART2 PRODUCT RANGE.


Mode d'emploi ACT SMART2 PRODUCT RANGE
Download
Manual abstract: user guide ACT SMART2 PRODUCT RANGE

Detailed instructions for use are in the User's Guide.

[. . . ] ACTsmart2 Product Range Operating and Installation Instructions 18-00045 ACTsmart2 Operating and Installation Manual Rev. 1. 3 Contents ORDERING INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INSTALLATION NOTES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 IMPORTANT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] See the two examples below: Adding a Card Batch with Arming Function: Step 1 2 3 4 5 6 Keypad Entry 10 Present Card Present Card 9 1-8, (optional)* Press Operation Add Card Batch First Card in Batch (lowest number card) Last Card in Batch (highest number card) Enable Arming mode (make sure Option 42 is set) Select each door this batch is valid for End Adding a PIN Code with Arming Function: Step 1 2 3 4 5 Keypad Entry 12 0001-9999 9 1-8, (optional)* Press Operation Add PINs (Make sure Option 40 is set on PIN and Prox Units) 4-6 digit PIN code Enable Arming mode (make sure Option 42 is set) Select each door this PIN is valid for End To summarise, the following steps are required for setting up tokens to arm and disarm alarm panels: 1. Program the ACTsmart2 to be an Arming Door - Option 42 On 2. Assign a card or PIN with the Arming function - see above. Assign an Aux I/O as the Door Armed output - I/O Function Code 14 4. If required, turn the Pulse Door Armed Option on - Option 43 On 5. If required, assign an input as the Panel Armed input. This input verifies when the alarm panel is actually armed. Connect up according to the Alarm Panel wiring diagram. 14 ACTsmart2 Operating and Installation Manual Rev. 1. 3 Programming ACTsmart2 Options: Step 1 2 3 4 Option 30 31 Keypad Entry 30-45 0 or 1 1-8, (optional)* Press Function Door Chime Silent Operation Operation Select Option Number 0 = Off, 1 = On Select each door this option is set for End setting options Default Off Off Operation When set, whenever the door contact is opened, the built-in buzzer makes a chime sound and the buzzer output activates for 2 seconds When set, the keypad operates silently. No audible tones (key-presses or confirm tones) are produced from the built-in buzzer When set, and when the door relay is active (following a valid code or button release), the door relay timer is truncated to 2 seconds when the door contact opens. This ensures that the door will be locked as soon as it closes, and any person following will have to enter a PIN or present a card. When set, the door relay toggles for each valid entry. The green LED flashes when the door is toggled open. When set, the buzzer output / door alarm output is activated if the door contact opens when the door is locked. The output is deactivated when a valid card or PIN is next entered. This is useful for monitoring fire doors etc. When set, and the door contact has been open for longer than the time programmed into the door ajar timer, the buzzer output / door alarm output is activated. Closing the door and presenting a valid card or entering a valid PIN deactivates the output. When set, (default) and when the key on the keypad is pressed, the buzzer output is activated for the duration programmed in the guest buzzer timer. When set, and when a duress PIN is entered, the door is opened normally and the Door Alarm output activated. A duress PIN is any valid PIN with one added to the last digit. The output will be reset when a valid user enters. [. . . ] Note: This deletes the Programming Card. 22 ACTsmart2 Operating and Installation Manual ACTsmart2 Standalone Installation Diagram 23 Rev. 1. 3 Access Control Technology, Unit C1, South City Business Centre, Tallaght, Dublin 24, Ireland. Tel: 353-1-4662570 Fax: 353-1-4520427 UK Locall: 0845 300 5204 Web: http://www. accesscontrol. ie E-mail: sales@accesscontrol. ie ACTsmart2 Operating and Installation Manual ACTsmart2 Fire Alarm Override Connections 24 ACTsmart2 Interlock Connections Rev. 1. 3 Access Control Technology, Unit C1, South City Business Centre, Tallaght, Dublin 24, Ireland. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT SMART2 PRODUCT RANGE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT SMART2 PRODUCT RANGE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag