[. . . ] · Install in a properly ventilated location, away from heaters, heat ducts and other heat producing devices. · Do not use with high-current devices such as hobby arc welders, hair dryers, and space heaters. Total power consumption of connected equipment must not exceed 1800 watts. [. . . ] · No user serviceable parts inside. Do not attempt servicing of this unit yourself. Refer servicing to qualified service personnel. · All Satellite/DSS, Cable, and Antenna cables must be grounded in accordance with Section 810 of the National Electrical Code and ANSI/NFPA No. Failure to comply with these codes will void all warranties regarding the GFA-5503.
Unpacking
Before each GFA-5503 left the factory, it was carefully inspected for physical imperfections as a routine part of ADCOM's systematic quality control. This, along with full operational and mechanical testing, should insure a product flawless in both appearance and performance. After you have unpacked the GFA-5503, inspect it for physical damage. Save the shipping carton and all packing materials, as they are intended to minimize the possibility of transportation damage, should the product ever need to be shipped again. In the unlikely event damage has occurred, notify your dealer immediately and request the name of the carrier so that a written claim to cover the damage can be initiated. Connect the AC power cords of all other products to the switched jacks on the rear panel labeled "accessories" j.
This exclamation point symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Grounding Screw
The grounding screw 1# provides a convenient system grounding point where one or more of the components is not equipped with a three prong AC cord. The entire
Operation
The unswitched front panel LED e indicates that AC current is passing through the GFA-5503 and into the components connected to the unswitched AC rear panel outlets 1). The unswitched LED e is always on provided the unit is plugged into an active AC source. To prevent turn-on thump, the jacks for the accessories and amplifiers have seperate relays. When the GFA-5503 is turned on, the accessories power up before the amplifiers. When powering down, the relay works in reverse. These delays are in effect both with the 12V trigger source, and without, and the duration may be adjusted by your authorized ADCOM dealer.
Trouble shooting
Symptom
-Unswitched LED does not come on when the GFA-5503 AC power cord is plugged into an outlet -Power button pushed in, but switched outlets are off and power LED glows amber -GFA-5503 does not respond to 12v input -No delay between accessories and amplifiers outlets
Possible Causes
-Outlet may be shut off at the main breaker box -Unit may be in standby mode -Remove any plug in the 12v trigger jack -Power button must be pressed in for remote activation -The trigger voltage maybe outside the allowable + (5-12) volts -Delay settings are incorrect. Return to authorized dealer for adjustment. Factory settings are approximately ten seconds for amplifier turn-on and thirty seconds for accessories turn-off.
Technical Specifications
Electrical Input power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120VAC, +/-10%, 5-/60Hz Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15A Circuit Breaker Internal Power Consumption. . . . . . . . . . . . . . . . . . . . . . . . . Less than 5 watts Control Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +/-5V to 24V AC/DC Total Output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15A Environmental: Operating Temperature. . . . . . . . . . . . . . . 0 to +50 C Storage Temperature. . . . . . . . . . . . . . . -40 to +80 C Filter Noise: Normal Mode. . . . . . . . . . . . . . . . -5dB at 5kHz; -38 dB at 300kHz Common Mode. . . . . . . . -3dB at 300kHz; -40 dB at 1 MHz Surge Protection Endurance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1, 000 surges 6 kV; 3 kA Clamping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 volts Response Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 sec. [. . . ] (Passive protection / always on) Maximum Applied Pulse (Combination Wave): · Voltage: 6, 000 volts · Current: Unlimited due to current limiting · Joules: Unlimited due to current limiting Mechanical Dimensions. . . . 17"(430mm) x 12" (305mm) x 3. 5"(89mm) Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 lbs. (2. 7 kg) AC Cord. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 ft. (1. 8m)
Servicing
ADCOM has a technical service department to answer questions pertaining to the installation and operation of your unit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ADCOM GFA-5503
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ADCOM GFA-5503 will begin.