Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ADEMCO VIA30PLUS. We hope that this ADEMCO VIA30PLUS user guide will be useful to you.
Lastmanuals help download the user guide ADEMCO VIA30PLUS.
Detailed instructions for use are in the User's Guide.
[. . . ] via30+,
VISTA 10, 411lX M
N7229 7194
ADEMCO
TABLE
SYSTEM OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OF CONTENTS
3 3 3 3 4 4 4 4 4 5 5 5 7 8 17 ARMING PERIMETER ONLY (INSTANT) . . . . . . . . . . . . . . . . . . . 18 ARMING ALL PROTECTION ARMING ALL PROTECTION (MAXIMUM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Power Failure
[f there present)
system If the is
is no console display at all, and the POWER indicator power for the system has stopped and is not lit, operating
inoperative. `!AC present) CALL LOSS" FOR or SERVICE "NO AC" is IMMEDIATELY. displayed, and the
(if
the
message (if
POWER
is off, the Console is operating on battery power only. If only some lights are out on the premises, check circuit breakers and fuses and reset or replace as necessary. CALL FOR SERVICE IMMEDIATELY if AC power cannot be restored.
indicator
TROUBLE
Other Displays Fixed-Word Consoles dl:
Conditions
cc:
FC:
Oc:
If this remains displayed for more than 1 minute, your system is disabled. The system is in communication with the central station for change of function or status verification. If this message persists for more than 10 minutes, CALL FOR SERVICE IMMEDIATELY. A communication failure with the central station has occurred. The console is not receivina sianals from the control panel and sees an open circuit. /f this rnessag; p%sts for more than 70 minutes, CALL FOR SERVICE IMMEDIATELY.
Partitioned
System
If your system is part of a Partitioned System, it can share one physical alarm system between two different users, each with their own requirements (e. g. , the occupants of a two family house). When so-configured, each partition operates
independently of the other, but from time to time display messages may appear temporarily on a console which indicate the other partition is in use (e. g. , during testing by an installer). Do not be concerned, This is normal.
FOR SERVICING INFORMATION, SEE PAGE 43
-28-
FIRE ALARM SYSTEM
IF INSTALLED General Your fire alarm system (if installed) is on 24 hours a day, for continuous protection. In the event of an emergency, the strategically located smoke and heat detectors will automatically send signals to your system, triggering a loud,
interrupted sound from the Console. An interrupted sound will also be produced by optional exterior sounders. A FIRE message will appear at your Console and
remain on until you silence the alarm.
[n Case Of
Fire Alarm
before your detectors sense 1. Should you become aware of a fire emergency the problem, go to your nearest Console and manually initiate an alarm by pressing the panic key pair assigned as FIRE emergency (if programmed by the installer) as indicated on page 23. Evacuate all occupants from the premises. If flames and/or smoke are present, leave the premises and notify your local Fire Department immediately. If no flames or smoke are apparent, investigate the cause of the alarm. The zone number(s) of the zone(s) in an alarm condition will be displayed at the Console.
TYPICAL
FIRE
EMERGENCY
DISPLAYS
-1 ALPHA
FIRE FIXED-WORD
29-
FIRE ALARM SYSTEM
IF INSTALLED Silencing Fire Alarms 1. Silence
silence
key the alarm by pressing the OFF key (security code not needed to fire alarms). To clear the display, enter your code and press the OFF (Memory of Alarm). [. . . ] Wireless transmitters (used with some systems) are designed to provide long battery life under normal operating conditions. Longevity of batteries may be as much as 4 to 7 years, depending on the environment, usage, and the specific wireless device being used. External factors such as humidity, high or low temperatures, as well as large swings in temperature, may all reduce the actual battery life in a given installation. This wireless system, however, can identify a true low battery situation, thus allowing time to arrange a change of battery to maintain protection for that given point within the system. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ADEMCO VIA30PLUS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ADEMCO VIA30PLUS will begin.