User manual ADEMCO VISTA-15PSIA PROGRAMMING GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ADEMCO VISTA-15PSIA. We hope that this ADEMCO VISTA-15PSIA user guide will be useful to you.

Lastmanuals help download the user guide ADEMCO VISTA-15PSIA.


Mode d'emploi ADEMCO VISTA-15PSIA
Download
Manual abstract: user guide ADEMCO VISTA-15PSIAPROGRAMMING GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems Programming Guide K5305-1PRV5 10/04 Rev. A TO ENTER PROGRAMMING MODE (using an alpha keypad connected to the control): A. POWER UP, then press [] and [#] at the same time, within 50 seconds of powering up (this method must be used if 98 was used to exit program mode). Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0. [. . . ] Press [] to return to the ENTER ZN NUM prompt. *5800 button-type transmitters only PARTITION 1, 2, or 3-common (VISTA-20P) REPORT CODE 1-9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F For Contact ID®, enter any non-zero entry as the first digit to enable reporting for this zone. To disable the report code for this zone, enter 00. 58 Expert Zone Programming Mode (press 58 while in Data Programming mode) SET TO CONFIRM? Select whether you want confirmation of wireless device enrollment. (See "XMIT TO CONFIRM" prompt later in this section. ) We recommend that you confirm the programming of every transmitter. HARDWIRE TYPE Appears only for zones 02-08. Zone 1 is automatically set for EOL operation. Enter the desired hardwire type: 0 = EOL; 1 = NC; 2 = NO; 3 = zone doubling (ZD); 4 = double-balanced (DB) ( VISTA-20P) SUMMARY SCREEN Zn ZT P RC HW: RT 01 09 1 10 EL 1 (Typical for Zone 1, initial summary screen) RESPONSE TIME For hardwired zones 01-08. Enter the desired response time for this zone: 0 = 10mSec; 1 = 350mSec; 2 = 700mSec; 3 = 1. 2 secs (see field 174). NOTE: If zone doubling is being used, the response time selected for zones 02-08 automatically applies to each zone's associated doubled zone. INPUT TYPE Skipped for zones 2-8, and for zones 10-16 if zone-doubling enabled. Enter the input type: 2 = AW (Aux wired zone); 3 = RF (supervised RF); 4 = UR (unsupervised RF); 5 = BR (unsupervised button type) NOTE: To change the input type of a previously programmed wireless device to a wired zone, you must first delete the transmitter's serial number. Zn ZT P RC IN: L 10 00 1 10 RF: ­ (Typical for entered zone number; zone 10 in this example) System displays summary of zone 1's current programming. Enter the zone number being programmed, then press []. A summary screen for that zone is displayed, along with any current programming values, and the cursor moves to the Zone Type location. The cursor then automatically moves to the next locations after each entry is made. Special Function Keys: · [A] (Advance) and [B] (Back) keys on the keypad move the cursor within the screen. · [C] (Copy) key will insert the previous zone's attributes, if desired. · [D] key starts the Wireless Key Programming Templates menu (see Wireless Key Programming Templates section that follows this section). Sequentially enter Zone Type (ZT), Partition (P), and Report Code (RC), then Hardwire Type (HW) and Response Time (RT) for basic wired zones 1-8 or Input Device Type (IN) for zones 9 and higher (Loop Number [L] is programmed at the INPUT S/N prompt). See *56 Zone Programming Menu Mode section described earlier for entry values. applies to VISTA-20P Press [] to save the programming and continue. If needed, press the [#] key to back up without saving. · For wireless devices (input types RF, UR, BR), continue to the INPUT S/N (serial number/loop number) and XMIT TO CONFIRM prompts described earlier in the *56 Zone Programming Menu Mode section. When done, the display returns to the initial summary screen prompt to let you program the next zone. · For wired devices, the display returns to the initial summary screen prompt to let you program the next zone. To Quit, enter 00 at the zone number location and press []. INPUT S/N Enroll the transmitter's serial number and loop number as follows: 1. [. . . ] USE 12V, 17. 2AH BATTERY FOR 600mA AUX POWER. SEE INSTRUCTIONS. BATTERY FUSE 3A FOR REPLACEMENT, USE SAME VALUE (e. g. 90-12) RELAY PROGRAM RELAY AS ZONE TYPE 54 (FIRE ZONE RESET) _4 BLK _ + RED BATTERY CAPACITY FOR EMERGENCY BURGLARY STANDBY USE AT LEAST 4 HRS 8-PIN CONNECTOR USED FOR 1361X10 TRANSFORMER CONNECTIONS AND FOR ON-BOARD TRIGGERS SEE INSTRUCTIONS. 1234 5 678 BLK RED GRN YEL AND/OR ADEMCO 5881* Type RF RECEIVER WIRELESS ZONES AUX PWR SET UNIT'S OUTPUT DIP SWITCH TERMINALS FOR DEVICE ADDRESSES 7 - 15 SEE OR INSTRUCTIONS. N. C. N. O. BATTERY 12V, 4AH RED BLACK CHARGING VOLTAGE 13. 8VDC. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ADEMCO VISTA-15PSIA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ADEMCO VISTA-15PSIA will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag