User manual ADVANTOR ADVANTAGE PLUS-TEL PLUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ADVANTOR ADVANTAGE PLUS-TEL PLUS. We hope that this ADVANTOR ADVANTAGE PLUS-TEL PLUS user guide will be useful to you.

Lastmanuals help download the user guide ADVANTOR ADVANTAGE PLUS-TEL PLUS.


Mode d'emploi ADVANTOR ADVANTAGE PLUS-TEL PLUS
Download
Manual abstract: user guide ADVANTOR ADVANTAGE PLUS-TEL PLUS

Detailed instructions for use are in the User's Guide.

[. . . ] No part of this document may be reproduced or distributed in any form or by any means, or stored in a database or retrieval system, without the prior written permission of Advantor Corporation. DESCRIPTION The TelPlus is an optional add-on unit that, when added to the Advantage plus Base Module, provides a second telephone line interface with the central monitoring console. You can configure the TelPlus for either a second dial telephone interface, or as the Advantage plus' primary dedicated telephone line then using the Base Module's telephone interface for a backup dial communication line. NOTE: You can configure the Base Module's telephone line connection for either dial line or dedicated line connection (but not both). Use the TelPlus to provide a second telephone line interface. [. . . ] MAKE SURE TelPlus DIAL jumpers JP1 and JP2 are installed, and jumpers JP3 and JP4 are removed. This configures the TelPlus for secondary dial line operation. Plug the RJ cord into the external jack, route into the chassis, and plug the other end to the TelPlus RJ jack (J2). Inside the RJ31X jack, connect the telephone line to pins 4 and 5, and connect the house telephone to pins 1 and 8. INSTALLATION TELPLUS OPTIONS 1. In the SONICS Modify-ASOP-Equipment screen, select the TelPlus Module. 1 Downloaded from - http://www. guardianalarms. net NOTE: All UL Fire and Burglary installations must use the fused RJ31X jack included in the ULB and ULF Installation Kits. To Primary House Phone 5 6 7 8 Base Module J8 To Dial Telco Line WARNING!Electrical shock hazard present during telephone line servicing. RING TIP DEDT DEDR -------------------------EGND -----XF2 DUPO ANS TLM ----------+12V ------ "Primary" Dial Line Connection 3. MAKE SURE TelPlus DED jumpers JP3 and JP4 are installed, and jumpers JP1 and JP2 are removed. This configures the TelPlus for primary dedicated line operation. Plug the RJ cord into the external jack, route into the chassis, and plug the other end to the TelPlus RJ jack (J2). NOTE: Wire the Base Module backup dial line identically to a Base Module primary dial line. OPTIONS DOWNLOADING WITH TELPLUS When using the TelPlus for dedicated line connection, always disconnect the dedicated line for the Base Module's initial options download. While in the Test Mode, the Base Module always assumes it is configured for dial line operation. 4 3 2 1 JP1 JP2 DIAL TELPLUS OPERATION TELPLUS REV "Secondary" Dial Line Connection To Secondary House Phone 5 6 7 8 JP3 JP4 DED 90227 SN: In Dial Line #2 operation, TelPlus relay K1 is turned on, connecting the TelPlus to the dial line through JP 1 and 2. In dedicated line operation, TelPlus relay K1 turns off, connecting the TelPlus to the dedicated line through JP 3 and 4. If the dial backup on the Base Module is needed, relay K1 turns on. 4 3 2 1 DIALING SEQUENCE RING TIP To Dial Telco Line EGND Cable to chassis EARTH GND stud Figure 1. TelPlus Secondary Dial Line Configuration PRIMARY DEDICATED LINE INSTALLATION The required RJ cord and external RJ31X jack are supplied in the installation kit. Refer to Figure 2 throughout the installation and setup procedure. Install the external RJ31X jack in a location near the Advantage plus chassis. Be sure to label the dedicated line RJ31X jack so a dial line is not plugged here by mistake. UL Fire and Burglary installations must use the fused RJ31X jack included in the ULB and ULF Installation Kits. Connect the dedicated line to pins 4 and 5 of the external RJ jack. [. . . ] All 24-Hour contact checks are performed at low traffic times, between 11 PM and 5 AM. 4 3 2 1 RING TIP To Dedicated Line EGND Cable to chassis EARTH GND stud Figure 2. TelPlus Primary Dedicated Line Configuration 2 ADVANTOR CORPORATION HARDWARE LIMITED WARRANTY STATEMENT Advantor Corporation warrants each new product of its manufacture, to be free from defects in material and workmanship. It will repair or replace defective parts for a period of 24 months from the date of manufacture, providing the equipment has not been subjected to abnormal conditions such as misuse, abuse, misapplication, alteration, lightning damage or damage by an Act of God. This excludes packing, handling and shipping charges from the Customer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ADVANTOR ADVANTAGE PLUS-TEL PLUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ADVANTOR ADVANTAGE PLUS-TEL PLUS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag