If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX 115DD. We hope that this AEG-ELECTROLUX 115DD user guide will be useful to you.
Lastmanuals help download the user guide AEG-ELECTROLUX 115DD.
Detailed instructions for use are in the User's Guide.
[. . . ] You also need an active carbon filter (special accessory). When outdoor temperatures become warmer (spring), the active carbon filter is removed again and the fume extractor hood reset to exhaust air operation as per installation sequence. The return air slots on the upper side of the appliance are to be sealed e. g. See also for exhaust air operation installation.
4
Electrical connections
Voltage and current Please ensure that the voltage and current indicated on the rating plate agree with the voltage of your electricity supply. [. . . ] We strongly recommend the appliance is connected by a qualified electrician who is a member of the NICEIC who will comply with the IEE and any local regulations. NOTE: The terminology "DOUBLE POLE" means that both the live and neutral supplies are swiched and disconnected at the same time. The terminations labelled SUPPLY are for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance. WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT The wires in this mains lead are coloured in accordance with the following code: Green/Yellow - Earth Blue - Neutral Brown - Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminate in your spur box, proceed as follows: The wire which is coloured green and yellow must be connected to the terminal which is marked with the letter "E" or by the earth symbol or coloured green or green and yellow. The wire which is coloured blue must be connected to the terminal which is marked with the letter "N" or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with the letter "L" or coloured red.
BLUE (NEUTRAL) BROWN (LIVE)
LOAD
L
N
FUSE ON
LOAD
L
SUPPLY DP 13A, 250V
N
SUPPLY
GREEN & YELLOW (EARTH)
7
Specifications
Dimensions: Height 152 Weight: Net: Gross: Width 599 Depth (in mm) 505
8. 7 Kg 9. 6 Kg
Length of the cable: 140 cm Maximum absorbed power: 230 W Motor absorption: 1 x 150 W Lighting: 2 x 40 W
Fan powers (levels), levels in compliance with DIN 44971 Level: Min. Extractor: 116 m3/h Filter: 60 m3/h Max. 175 m3/h 14 5 m3/h Intensive 265 m3/h 175 m3/h
Extractor system: 100 and 120 mm Ø
8
Installation
Safety warnings for kitchen unit installer When used as an extractor unit, the hood must be fitted with a 100 or 120 mm diameter hose. If the outlet hose is installed in a horizontal position, it must be slanted at an angle of 10° so that the air can flow outside without impediment. When installing the hood, make sure you respect the following minimum distance from the top edge of the cooking hob/ ring surfaces: electric cookers gas cookers coal and oil cookers 650 mm 650 mm 700 mm min.
The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed. It is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct. The air outlet installation must comply with the regulations laid down by the relevant authorities. When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole. National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room. Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood. If you have any doubts, contact the relevant controlling authority or building inspector's office. Where flexible ducting is fitted the length should be no more than: -- 3 metres with one 90° bend -- 2 metres with two 90° bends. Bends of more than 90° will reduce the efficiency of the hood and reduce the air flow.
9
Since the rule for rooms with fuel burning appliances is "outlet hole of the same size as the ventilation hole", a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood. If the hood is used in its recirculating mode, it will operate simply and safely in the above conditions without the need for any of the aforementioned measures. When the hood is used in its extractor function, the following rules must be followed to obtain optimal operation: -- short and straight outlet hose -- keep bends in outlet hose to a minimum -- never install the hoses with an acute angle, they must always follow a gentle curve only -- keep the hose as large as possible (100 or 120 mm Ø min. ). [. . . ] Never insert pointed objects in the motor's protective grille. Wash the outside surfaces using a delicate detergent solution. Never use caustic detergents or abrasive brushes or powders. Only ever clean the switch panel and filter grille using a damp cloth and delicate detergents. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX 115DD
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.