User manual AEG-ELECTROLUX 11602G

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX 11602G. We hope that this AEG-ELECTROLUX 11602G user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX 11602G.


Mode d'emploi AEG-ELECTROLUX 11602G
Download
Manual abstract: user guide AEG-ELECTROLUX 11602G

Detailed instructions for use are in the User's Guide.

[. . . ] 20604 G - 21604 G 11602 G - 21602 G Gaskookplaat Table de cuisson Gas hob Gebruiksaanwijzing en Installatievoorschrift Notice dutilisation et dencastrement Operating and Installation Instructions NL FR GB ENGLISH Important Safety Information GB You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 350350 Installation l This hob must be installed by qualified personnel, according to the manufacturers instructions and to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. Remove all packaging before using the hob. [. . . ] A well moistened soap impregnated steel wool pad can be used with caution, if the marks are particularly difficult to remove. After cleaning, be sure to wipe dry with a soft cloth. 41 Something Not Working? If the hob is not working correctly, please carry out the following checks before contacting your local AEG Service Force Centre. SYMPTOM n SOLUTION u There is no spark when lighting the gas Check that the unit is plugged in and the electrical supply is switched on Check that the RCCB has not tripped (if fitted) Check the mains fuse has not blown Check the burner cap and crown have been replaced correctly, e. g. Check the main jet is not blocked and the burner crown is clear of food particles. Check the burner cap and crown have been replaced correctly, e. g. after cleaning. u u u n The gas ring burns unevenly u u If after all these checks, your hob still does not operate correctly, contact your local AEG Service Force Centre. Please note that it will be necessary to provide proof of purchase for any in-guarantee service calls. In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown. 42 Service and Spare Parts If you require spare parts or an engineer contact your local Service Force Centre by telephoning: 0870 5 929 929 Your call will be routed to your local Service Force Centre. For the address of your local Service Force Centre and further information about Service Force, please visit the website at www. serviceforce. co. uk When you contact the Service Centre, they will need the following information: 1. Clear and concise details of the fault 4. The model and the serial number (see rating label on the back of this instruction booklet) 5. Before you move, please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Germany Italy Sweden UK Senlis Nürnberg Pordenone Stockholm Slough +33 (0)3 44 62 29 29 +49 (0)800 234 7378 +39 (0)800 117511 +46 (0)8 672 53 60 +44 (0)1753 219899 44 Instructions for the Installer Engineer technical data OVERALL DIMENSIONS CUT OUT DIMENSIONS SUPPLY CONNECTIONS Width: 580 mm. Gas: R 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. IGNITION HT SPARK Spark Generator Ispra Control's BF 80066 - 220-240V 0. 6 VA T120 Spark Gap : Fixed HEAT INPUT Rear Left Burner (semi rapid) Front Left Burner (rapid) Rear Right Burner (semi rapid) Front Right Burner (auxiliary) APPLIANCE CLASS APPLIANCE CATEGORY GAS SUPPLY 2. 0 kW (6824 BTU/HR) 3. 0 kW Natural Gas (10236 BTU/HR) 2. 8 kW L. P. G. (9554 BTU/HR) 2. 0 kW (6824 BTU/HR) 1. 0 kW (3412 BTU/HR) 3 II2H3+ Natural gas G20 / 20mbar 45 BURNER TYPE OF GAS POSITION NOMINAL THERMAL POWER kW RAPID (large) MAX MIN SEMI-RAPID (medium) MAX MIN AUXILIARY (small) MAX MIN NATURAL GAS NOMINAL FLOW 20 mbar VALUE = RATE m3/h 37. 78 MJ/m 3 Ws - 50. 7 MJ/ m3 NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE g/h 3. 0 0. 286 119 0. 65 0. 057 Adjust. 2. 0 0. 190 96 0. 45 0. 038 Adjust. 1. 0 0. 095 70 0. 33 0. 028 Adjust. LPG GAS 28-30/37 mbar VALUE = 49. 92 MJ/Kg 2. 8 202 86 0. 65 43. 5 40 2. 0 144 71 0. 45 29 32 1. 0 72 50 0. 33 21, 5 28 NOZZLE REFERENCE 1/100 mm Burner Auxiliary Semi-rapid Rapid Dia. Tap By-pass 1/100 mm 28 32 40 Aeration adjustment none 46 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. [. . . ] Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit. If meter reads less than × (infinity) there is a fault. NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i. e. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX 11602G

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX 11602G will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag