If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX 34604G-M. We hope that this AEG-ELECTROLUX 34604G-M user guide will be useful to you.
Lastmanuals help download the user guide AEG-ELECTROLUX 34604G-M.
Manual abstract: user guide AEG-ELECTROLUX 34604G-M
Detailed instructions for use are in the User's Guide.
[. . . ] 21601C/ 34611C/ 35601C/ 35610C 35600G/ 35601G/ 35602G/ 34604G 35604G
Gas hob Table de cuisson Gaskookplaat Piano di cottura
AUS ERFAHRUNG GUT
Operating and Installation Instructions Notice dutilisation et dencastrement Gebruiksaanwijzing en Installatievoorschrift Istruzioni per luso e linstallazione
GB FR NL IT
ENGLISH
Important Safety Information
You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 350350
Installation
l
This hob must be installed by qualified personnel, according to the manufacturers instructions and to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. Remove all packaging before using the hob. [. . . ] The guarantee or free replacement includes both labour and material. Repairs carried out under guarantee do not extend the guarantee period for the appliance. Parts removed during guarantee repairs become property of AEG. The purchasers statutory rights are not affected by this guarantee.
European Guarantee
If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications: * The guarantee starts from the date you first purchased your product. * The guarantee is for the same period and to the same extent for labour and parts as exist in the new country of use for this brand or range of products. * This guarantee relates to you and cannot be transferred to another user. * Your new home is within the European Community (EC) or European Free Trade Area. * The product is installed and used in accordance with our instructions and is only used domestically, i. e. a normal household * The electrical supply complies with the specification given in the rating label. * The product is installed taking into account regulations in your new country. Before you move, please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Germany Italy Sweden UK Senlis Nürnberg Pordenone Stockholm Slough +33 (0) 3 44 62 29 29 +49 (0) 800 234 7378 +39 (0) 800117511 +46 (0) 8 672 53 60 + 44 (0) 1753 219899
10
Instructions for the Installer
Engineers technical data
Overall dimensions Width: Depth: Cut out dimensions Width: Depth: 580 mm. 470 mm.
Heat Input
Rear Left Burner (semi rapid) Front Left Burner (rapid) 2. 0 kW (6824 BTU/HR)
Supply Connections Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. Ignition HT Spark Spark Generator:Ispra Control's BF 50046 230-240V 0. 6 YA T120 Spark Gap : Fixed
BURNER
3. 0 kW Natural Gas (10236 BTU/HR) 2. 8 kW L. P. G. Any gas installation must be carried out by a CORGI registered installer. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored.
13
FO 0814
FO 0264
A) End of shaft with nut B) Washer C) Elbow
On the end of the shaft, which includes the G 1/2" threaded elbow, adjustment is fixed so that the washer is fitted between the components as shown in the diagram. Screw the parts together without using excessive force.
Gas Connection
Connection to the gas supply should be with either rigid or semi-rigid pipe, i. e. The connection should be suitable for connecting to R 1/2" (1/2 BSP male thread). When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. Ensure that the main connection pipe does not exert any strain on the hob. It is important to install the elbow correctly, with the shoulder on the end of the thread, fitted to the hob connecting pipe. [. . . ] Rectify any fault.
Earth Wire Green/Yellow Neutral Wire Blue
SOCKET (face view)
()
FUSE
E( )
N
L
Isolate appliance and carry out: B: Insulation check. Rectify any fault including replacing fuses as necessary.
20
A. EARTH CONTINUITY CHECK Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary. Test leads from any appliance earth point to earth pin on plug. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX 34604G-M
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.