Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX 4000F-W. We hope that this AEG-ELECTROLUX 4000F-W user guide will be useful to you.
Lastmanuals help download the user guide AEG-ELECTROLUX 4000F-W.
Manual abstract: user guide AEG-ELECTROLUX 4000F-W
Detailed instructions for use are in the User's Guide.
[. . . ] 28÷36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37÷45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46÷54
Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] For the type "A" mounting, use the plate supports provided to ensure that the genset is fixed securely. If type "B" mounting is preferred (traditional installation), a watertight compartment (fig. 2), set towards the vehicle interior and having the dimensions given in section 1. 3. 3, needs to be prearranged, with exhaust holes and air inlets drilled into the floor and door. 4), supplied as accessory, to be fixed directly onto the generator casing with screws or rivets. In order to prevent the exhaust gas recycling within the compartment, place flameproof sealing around the exhaust union.
Power cables Battery recharger Battery connection TAB. 1
2. 3. 1 CONNECTION OF BATTERY RECHARGER
Use a wire with minimum cross-section according to table 1 above to connect the terminal (pos. 6 and 14) to the positive lead of the battery to be recharged. Insert the AG111 voltage regulator, or alternatively a switch, to interrupt recharging when complete. (See wiring diagrams, pages 55 ÷ 71).
2. 3. 2 CONNECTION OF STARTER BATTERY
For starting the generator, connect the positive terminal of the vehicle's starter battery to pos. 6 and 14 using a flame-resistant sheathed cable having a cross-section according to table 1 above. The earth cable should have the same cross-section and be connected from pos. The unit comes in a soundproof casing made of pressed steel plate and insulated with special deadening materials. Fuel comes to the combustion engine through a pump which is standard fitted on the unit itself.
3. 2
SAFETY ADVICE
The unit is housed within a perfectly closed casing. Therefore, there is no danger of accidental contacts with hot or moving parts or wires under voltage. The door of the unit is fitted with lock and key and should not be left within the reach of children or non-authorised persons.
4
FORLI'
Italy
4. 0 4. 1
INSTRUCTIONS FOR USE STARTING THE GENERATOR
4. 4
IMPROPER USE
DANGER
The generator is to be installed by qualified technicians only, according to the manufacturer's instructions. The generator is to be used only and exclusively for producing current for mobile vehicles, fitted with a standard electrical circuit in keeping with the power supplied by the generator.
Normally the vehicle's 12V battery is used to start the genset. 5) on the control panel into the "I" position. To start the genset from cold, press and hold down the green START button (pos. 1
To start the genset when already warmed-up, or during the summer, when the outside temperature is high, press the green "START" button (pos. In an emergency the genset can be started manually using the pull-cord handle (pos. 8 and 15) and holding the choke magnet (pos. 8 and 15) shut with one hand if the engine is cold. [. . . ] Adjust, if necessary, by bending the side electrode. Check that the spark plug washer is in good condition and screw it manually to prevent it being set at an angle. Once mounted, tighten the spark plug using a wrench with the right driving torque.
7
FORLI'
Italy
IMPORTANT
When mounting a new spark plug, tighten it a half-turn after it has compressed the washer. When re-using the same spark plug, tighten it 1/8-1/4 turn after the washer compression.
CAUTION
The spark plug should be tightened carefully. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX 4000F-W
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX 4000F-W will begin.