Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX 65402G-M. We hope that this AEG-ELECTROLUX 65402G-M user guide will be useful to you.
Lastmanuals help download the user guide AEG-ELECTROLUX 65402G-M.
Manual abstract: user guide AEG-ELECTROLUX 65402G-M
Detailed instructions for use are in the User's Guide.
[. . . ] 65402 G 65852 G
Instruction Booklet
Gas Hob
GB
IE
2
3
Contents
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Instructions for the User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Description of the Hob . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Make sure pots do not protrude over the edges of the cooktop and that they are centrally positioned on the rings in order to obtain lower gas consumption. Do not place unstable or deformed pots on the rings: they could tip over or spill their contents, causing accidents. A well moistened soap impregnated steel wool pad can be used with caution, if the marks are particularly difficult to remove. After cleaning, be sure to wipe dry with a soft cloth.
The Ignition Electrode
The electric ignition is obtained through a ceramic electrode which contains a metal electrode (Fig. Keep these components very clean, to avoid difficult lighting, and check that the burner crown holes (Fig. 1 - B) are not obstructed.
12
Something Not Working?
If the hob is not working correctly, please carry out the following checks before contacting your local Service Force Centre.
SYMPTOM There is no spark when lighting the gas.
SOLUTION Check that the unit is plugged in and the electrical supply is switched on. Check that the RCCB has not tripped (if fitted). Check the burner cap and crown have been replaced correctly, e. g. Check the main jet is not blocked and the burner crown is clear of food particles. Check the burner cap and crown have been replaced correctly, e. g. after cleaning.
The gas ring burns unevenly.
If after all these checks, your hob still does not operate correctly, contact your local Service Force Centre. Please note that it will be necessary to provide proof of purchase for any inguarantee service calls. In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown.
13
Instructions for the Installer
Engineer technical data
OVERALL DIMENSIONS Width: Depth: Width: Depth: 594 mm 510 mm 560 mm 480 mm
CUT OUT DIMENSIONS
SUPPLY CONNECTIONS
Gas: R 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230 V~ 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge
fuse. HEAT INPUT Rear Left Burner (semi rapid) Front Left Burner (semi rapid) Rear Right Burner (Mod. 65852) (triple crown) Rear Right Burner (Mod. 65402) (rapid) Front Right Burner (auxiliary) APPLIANCE CLASS APPLIANCE CATEGORY GAS SUPPLY 2. 0 kW (6826 BTU/HR) 2. 0 kW (6826 BTU/HR) 4. 0 kW (13652 BTU/HR) 3. 0 kW Natural Gas (10239 BTU/HR) 2. 8 kW LPG (9556 BTU/HR) 1. 0 kW (3413 BTU/HR)
3 II2H3+ Natural gas G20 (2H) / 20 mbar
This appliance is manufactured according to the following EEC directives: 2006/95 EEC - 93/68 EEC - 89/336 EEC - 90/396 EEC, current edition.
14
BURNER
RAPID
SEMI-RAPID A U X I L I A R Y TRIPLECROWN
TYPE OF GAS
POSITION M A X MIN M A X MIN M A X MIN MAX MIN
NATURAL GAS 20 mbar VALUE = 37. 78 MJ/m 3 Ws - 50. 7 MJ/ m3
NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE g/h NOZZLE REFERENCE 1/100mm
3. 0
0. 75
2. 0 0. 190 96
0. 45 0. 038 Adjust.
1. 0 0. 095 70
0. 33 0. 028 Adjust.
4. 0 0. 381 146
1. 2 0. 114 Adjust.
0. 286 0. 057 119 Adjust.
LPG GAS 28-30/37 mbar VALUE = 49. 92 MJ/Kg
2. 8 202 86
0. 75 43. 5 42
2. 0 144 71
0. 45 29 32
1. 0 72 50
0. 33 21, 5 28
4. 0 288 98
1. 2 86 56
15
Important Safety Requirements
This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I. S. 813 Current Editions and the ETCI Rules for Electrical Installations. Provision for Ventilation Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 100 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. [. . . ] The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar. 4) Turn off the burner supplies.
27
Conversion from Natural Gas to Liquid Gas
IMPORTANT
The replacement/conversion from natural gas to LPG should only be undertaken by a competent person.
It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted. The gas rate is adjusted to suit.
Method
1) Ensure that the gas taps are in the 'OFF' position 2) Isolate the hob from the electricity supply 3) Remove all pan supports, burner caps, rings, crowns and control knobs. 4) With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injectors.
TO ADJUST THE GAS RATE
With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX 65402G-M
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX 65402G-M will begin.