User manual AEG-ELECTROLUX 75552G-M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX 75552G-M. We hope that this AEG-ELECTROLUX 75552G-M user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX 75552G-M.


Mode d'emploi AEG-ELECTROLUX 75552G-M
Download
Manual abstract: user guide AEG-ELECTROLUX 75552G-M

Detailed instructions for use are in the User's Guide.

[. . . ] 75552G Gas hob Operating Instructions GB IE Important Safety Information You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 350350 Installation This appliance must be installed and serviced by a competent person as stated in the Gas Safety ( Installation and Use) Regulations Current Editions and the IEE Wiring Regulations. For appliances installed in the Republic of Ireland please refer to NSAI-Domestic Gas Installations I. S. 813 Current Editions and the ETCI Rules for Electrical Installations. Remove all packaging before using the hob. [. . . ] · The appliance has not been serviced, maintained, repaired, taken apart or tampered with by any person not authorised by us. · All service work under this guarantee must be undertaken by a Service Force Centre. Any appliance or defective part replaced shall become the Company's property. · This guarantee is in addition to your statutory and other legal rights. · Home visits are made between 8. 30am and 5. 30pm Monday to Friday. Visits may be available outside these hours in which case a premium will be charged. Exclusions This guarantee does not cover: · · · · Damage or calls resulting from transportation, improper use or neglect, the replacement of any light bulbs or removable parts of glass or plastic. 146 Adjust. LPG GAS 28-30/37 mbar VALUE = 49. 92 MJ/Kg 2. 8 202 86 0. 65 47 40 2. 0 144 71 0. 45 32 32 1. 0 72 50 0. 33 24 28 4. 0 288 98 1. 2 86 56 11 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I. S. 813 Current Editions and the ETCI Rules for Electrical Installations. Provision for Ventilation Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic Gas Installation I. S. 813 Current Editions Table Four. Location The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room. Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm between the edge of the hob and the wall. The minimum distance combustible material can be fitted above the hob is 400 mm. a space of 50 mm must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm. [. . . ] Resistance should be less than 0. 1 (Ohm), check all earth wires for continuity and all contacts are clean and tight. INSULATION CHECK Appliance electrically disconnected, all switches ON. Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX 75552G-M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX 75552G-M will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag