Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX 835D-M. We hope that this AEG-ELECTROLUX 835D-M user guide will be useful to you.
Lastmanuals help download the user guide AEG-ELECTROLUX 835D-M.
Detailed instructions for use are in the User's Guide.
[. . . ] If the appliance has been equipped with a mains lead with a moulded-on type plug, the following regulations must be comply with: The plug moulded on to the lead incorporates a fuse. For replacement, use a 5 amp BS1362 fuse. Only ASTA approved or certified fuses should be used. If the fuse cover/carrier is lost, a replacement cover/carrie must be obtained from an electrical goods retailer. [. . . ] q It is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct. The air outlet installation must comply with the regulations laid down by the relevant authorities. q When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole. q National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room. q The national decree on fuel-burning systems specifies a maximum depression of 0. 04 bar in such rooms. q Hoods can only be used safely with appliances connected to
24
a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood. If you have any doubts, contact the relevant controlling authority or building inspector's office. q Since the rule for rooms with fuel burning appliances is "outlet hole of the same size as the ventilation hole", a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood. q If the hood is used in its filtering function, it will operate simply and safely in the above conditions without the need for any of the aforementioned measures. q When the hood is used in its extractor function, the following rules must be followed to obtain optimal operation: -- short and straight outlet hose -- keep bends in outlet hose to a minimum -- never install the hoses with an acute angle, they must always follow a gentle curve only -- keep the hose as large as possible (150 mm Ø min. ). q Failure to observe these basic rules will drastically reduce the performance and increase the noise levels of the extractor hood.
25
Installation - Fig. 3
q Put the template onto the wall (1) and drill two Ø12mm holes (2). q Fit two hooks (3) on the drilled holes. q Hang the hood on the hooks and adjust the position of the hood using the two screws on the bottom of the hooks (5). q Remove the metal filters (4) and mark two points (6). Remove the hood and drill two Ø8mm holes on the marked points. Fit two Ø8mm wall dowels (7), Hang again the hood and fix the hood definitively with two screws 5X45 (8). q Fix the chimney support (10) with two screws 5 x 45 mm (9) and two wall dowels (11) on the wall close to the ceiling. q For exhausting version: Fit the connection ring (S) on the top of the hood with two screws Ø 3, 5 x 6, 5 mm (12S) then fit an exhausting pipe long enough to reach the outside (13S). For recycling version: Fix definitively the deflector (13K) on the top of the hood with two screws Ø 3, 5 x 6, 5 mm (12K). q Prepare the electric connection (14) (see relative chapter). q Fit the chimney (15) and fix it on the chimney support with two screws 3, 0 x 9 mm (16). [. . . ] Dishwasher machine Place grease filters in dish washer. Select most powerful washing programme and highest temperature, at least 65°C. Refit the grease filters when it are dry. When washing the metal grease filter in the dishwasher a slight discoloration of the filter can occur, this does not have any impact on its performance. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX 835D-M
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX 835D-M will begin.