If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX 99852G-M. We hope that this AEG-ELECTROLUX 99852G-M user guide will be useful to you.
Lastmanuals help download the user guide AEG-ELECTROLUX 99852G-M.
Manual abstract: user guide AEG-ELECTROLUX 99852G-M
Detailed instructions for use are in the User's Guide.
[. . . ] B 99852G
User Manual
Hob
Important Safety Information
You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 350350
Installation
This appliance must be installed and serviced by a competent person as stated in the Gas Safety ( Installation and Use) Regulations Current Editions and the IEE Wiring Regulations. For appliances installed in the Republic of Ireland please refer to NSAI-Domestic Gas Installations I. S. 813 Current Editions and the ETCI Rules for Electrical Installations. Remove all packaging before using the hob. [. . . ] Please note that it will be necessary to provide proof of purchase for any inguarantee service calls. In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown.
10
Instructions for the Installer
Instructions for the Installer
Engineers technical data
Overall dimensions
Width: Depth: 880 mm 510 mm Burner Auxiliary Semi-rapid Ultra-rapid Aeration adjustment none Semi-rapid Burner 1. 9 kW (6, 483 BTU/HR) Auxiliary Burner 1. 0 kW (3, 412 BTU/HR) Appliance class 3 Appliance category II2H3+ Gas supply Natural gas G 20 / 20 mbar Dia. Tap By-pass 1/100 mm 28 32 56
Cut out dimensions
Width: Depth: 830 mm 480 mm
Supply Connections
Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230 V 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. Heat Input Ultra-rapid Burner 3. 8 kW Natural Gas (Triple crown) (12, 966 BTU/HR) 3. 8 kW L. P. G. (12, 966 BTU/HR)
BURNER
TYPE OF GAS
POSITION NOMINAL THERMAL POWER (kW) NOMINAL FLOW RATE (m3/h) NOZZLE REFERENCE (1/100 mm) NOMINAL THERMAL POWER (kW) NOMINAL FLOW RATE (g/h) NOZZLE REFERENCE (1/100 mm)
ULTRA-RAPID (triple crown) MAX MIN
SEMI-RAPID (medium) MAX MIN
AUXILIARY (small) MAX MIN
NATURAL GAS 20 mbar VALUE = 37. 78 MJ/m 3 Ws - 50. 7 MJ/ m3
3. 8 0. 362 146
1. 20 0. 114 Adjust.
1. 9 0. 181 96
0. 45 0. 043 Adjust.
1. 0 0. 095 70
0. 33 0. 028 Adjust.
LPG GAS 28-30/37 mbar VALUE = 49. 92 MJ/Kg
3. 8 274 98
1. 20 86 40
1. 9 137 71
0. 45 32. 4 32
1. 0 72 50
0. 33 23. 8 28
11
Instructions for the Installer
Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I. S. 813 Current Editions and the ETCI Rules for Electrical Installations. Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. Any gas installation must be carried out by a registered competent person. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored. On the end of the shaft, which includes the GJ 1/2" threaded elbow, adjustment is fixed so that the washer is fitted between the components as shown in the diagram. Screw the parts together without using excessive force.
Gas Connection
Connection to the gas supply should be with either rigid or semi-rigid pipe, i. e. The connection should be suitable for connecting to RC 1/2 (1/2 BSP male thread). When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. Ensure that the main connection pipe does not exert any strain on the hob.
FO 0814
FO 0264
A) Ramp with ending nut B) Seal C) Elbow
It is important to install the elbow correctly, with the shoulder on the end of the thread, fitted to the hob connecting pipe. Failure to ensure the correct assembly will cause leakage of gas. 13
Instructions for the Installer
Cut Out Size
The dimensions of the cut-out are given in the diagram.
51 0
880
480
30
830
FO 2349
150 min
Building In
Building over a cupboard or drawer
If the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside of the work surface. It is also recommended to carry out the electrical connection to the hob as shown in diagrams 1 and 2 (See next page).
14
Instructions for the Installer
1
ON/OFF SWITCH
2
ON/OFF SWITCH
FLEX OUTLET
FLEX OUTLET
FO 0763
FO 0764
Building over a kitchen unit with door
Proper arrangements must be taken in designing the furniture unit, in order to avoid any contact with the bottom of the hob which can be heated when it is operated. The recommended solution is shown in diagram 3. The panel fitted under the hob ("a") should be easily removable to allow easy access if technical assistance is needed. The space behind the kitchen unit ("b") can be used for connections.
30
3
a b
60
FO 1013
Dimensions are given in mm.
20 min
15
Instructions for the Installer
Fitting the hob to the worktop
Before fitting the hob into the cut out, an adhesive seal must be fitted to the underside outside edge of the hob. It is essential that no gaps are left in this seal in order to prevent spillage near the hob seeping into the cabinet below. [. . . ] Repeat this procedure for all burners.
Minimum adjustment screw
Pressure Testing
1) Remove left hand pan support and front left burner cap and crown. 2) Fit manometer tube over the injector. 3) Turn on the burner gas supply and ignite another burner supply. The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX 99852G-M
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.