User manual AEG-ELECTROLUX CHDD8795M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX CHDD8795M. We hope that this AEG-ELECTROLUX CHDD8795M user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX CHDD8795M.


Mode d'emploi AEG-ELECTROLUX CHDD8795M
Download
Manual abstract: user guide AEG-ELECTROLUX CHDD8795M

Detailed instructions for use are in the User's Guide.

[. . . ] Failure to do so could cause grease deposits to build up, resulting in a fire hazard. For the installer · When used as an extractor unit, the hood must be fitted with a 150mm diameter hose. · Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof, it is possible to use the 150/125 mm reduction flange provided. In this case the hood will be slightly noisier. · When installing the hood, make sure you respect the following minimum distance from the top edge of the cooking hob/ring surfaces: electric cookers 300 mm gas cookers 300 mm coal and oil cookers 400 mm min. [. . . ] 3 Depress the control ball towards the top : once for submersed lighting, once again for full lighting, depress again to switch off the light. Indicator light for grease or charcoal filter The air duct, in this hood, includes a device that signals when the filter requires cleaning or changing . depress towards the top to switch on the lights Fig. 3 Led signal for grease filter The LED signal flickers (flickering green light) when the grease filter requires cleaning, occurs at about 40 operating hours. Ensure that the indicator light is checked each time the hood is used. Led signal for charcoal filter The LED signal flickers (flickering orange light) when the charcoal filter requires cleaning, occurs at about 160 operating hours. Ensure that the indicator light is checked each time the hood is used. Re-setting the saturation signal After cleaning or replacing the filter, select the intensive speed (the control ball lights up with a red flashing light), depress again and hold depressed for about 3 seconds until an audible signal indicates the reset has taken place. 58 Maintenance and care · The hood must always be disconnected from the electricity supply before beginning any maintenance work. Cleaning the hood · Clean the outside of the hood using a damp cloth and a mild detergent. · Never use corrosive, abrasive or flammable cleaning products. · Never insert pointed objects in the motor's protective grid. · Wash the outside surfaces using a delicate detergent solution. Never use caustic detergents or abrasive brushes or powders. · Only ever clean the switch panel and filter grille using a damp cloth and delicate detergents. · It is extremely important to clean the unit and change the filters at the recommended intervals. Failure to do so will cause grease deposits to build up that could constitute a fire hazard. Metal grease filter · The purpose of the grease filters is to absorb grease particles which form during cooking and it must always be used, either in the external extraction or internal recycling function. Attention: the metal grease filters must be removed and washed, either by hand or in the dishwasher, every four weeks. · To access the grease filter, first remove the front panels Extract which conceal the grease filter. Removing the front panels: Extract the small panel, rotate upwards and unhook. Repeat the operation for all the small panels. 4 59 Removing the metal grease filter Pull the handle downards, then extract the filter. Fig. 5. Handle Hand washing Soak grease filter(s) for about one hour in hot water with a greaseFig. 5 loosening cleaner, then rinse off thoroughly with hot water. Refit the grease filters when they are dry. Dishwasher Place grease filters in the dishwasher. Select most powerful washing programme and highest temperature, at least 65°C. Refit the grease filters when they are dry. When washing the metal grease filter in the dishwasher a slight discolouration of the filter can occur, this does not have any impact on its performance. [. . . ] Cover the drill holes for screws with the two screw caps provided. 4 4 6 5 5 3 7 8 6 8 2 1 9 Fig. 9 67 · Fix the sides of the cooker hood by 11 fastening the pins (10a) to the sides of the fastening screws (10b). Only DD 8794 (not UK): side panels are available as a special accessory 10a please contact your local Service Centre (or see paragraph "Special Accessory"). · Make electrical connection (12), but leave the hood disconnected from the home general electric panel. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX CHDD8795M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX CHDD8795M will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag