User manual AEG-ELECTROLUX CHDD8890-A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX CHDD8890-A. We hope that this AEG-ELECTROLUX CHDD8890-A user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX CHDD8890-A.


Mode d'emploi AEG-ELECTROLUX CHDD8890-A
Download
Manual abstract: user guide AEG-ELECTROLUX CHDD8890-A

Detailed instructions for use are in the User's Guide.

[. . . ] DD 8890 - CHDD 8820 CHDD 8890 Dunstabzugshaube Afzuigkap Hotte Cooker Hood Campana extractora Montage- und Gebrauchsanweisung Installatie- en gebruiksaanwijzing Notice dutilisation et dinstallation Operating and Installation Instructions Instrucciones de montaje y manejo Contents Safety warnings For the user For the installer Description of the Appliance Extractor version Filter Version Control Panel Control device for grease and charcoal filters Grease filter LED (F) Charcoal filter LED (C) Resetting the saturation indicator Maintenance and care Cleaning the hood Metal grease filter Removing the metal grease filter Charcoal filter Changing the light bulb What to do if Special accessories Technical assistance service Technical Specifications Mounting accessories included Electrical connection Wall unit mounting 53 53 53 55 55 55 56 57 57 57 57 58 58 58 58 59 60 61 62 62 63 63 64 65 Printed on recycled paper AEG - putting words into action 52 Safety warnings For the user The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames. Also, when frying, keep the deep frying pan on the cooker top/ cooker under careful control. [. . . ] Should the hood or the controls fail to operate: disconnect the power supply for at least 5 seconds. After reconnecting the power supply wait 15 seconds and then check that the cooker hood is now operating correctly. 56 Control device for grease and charcoal filters This hood is fitted with a device that signals when it is necessary to clean the grease filter or the charcoal filter (if the hood is used in the recirculation version with a charcoal filter). On delivery, the hood is not supplied with a charcoal filter, so the saturation indicator will be disabled. If the hood is to be used with a charcoal filter, the saturation indicator light must be enabled as follows: Press buttons 4 and 5 simultaneously and hold them for 3 seconds. At first only the grease filter LED F will illuminate, but when the charcoal filter LED C illuminates the saturation indicator will be enabled. To disable it: Press buttons 4 and 5 again simultaneously and hold them for 3 seconds, until the charcoal filter LED C goes out. Grease filter LED (F) LED F will start to flash when it is time to clean the grease filter. Cleaning will be necessary after 40 working hours. Always comply with the maintenance instructions for the grease filter. Charcoal filter LED (C) The charcoal filter LED C will start to flash when the charcoal filter needs to be replaced. This operation is necessary after approximately 160 working hours. Resetting the saturation indicator After cleaning or replacing the filters, press button 1 for 3 seconds until the grease filter LED F or the charcoal filter LED C stops flashing. The resetting of the saturation indicator MUST be done in stand-by, never disconnect the hood from the mains. 57 Maintenance and care The hood must always be disconnected from the electricity supply before beginning any maintenance work. Cleaning the hood Clean the outside of the hood using a damp cloth and a mild detergent. Never use corrosive, abrasive or flammable cleaning products. Never insert pointed objects in the motors protective grid. Wash the outside surfaces using a delicate detergent solution. Never use caustic detergents or abrasive brushes or powders. Only ever clean the switch panel and filter grille using a damp cloth and delicate detergents. It is extremely important to clean the unit and change the filters at the recommended intervals. Failure to do so will cause grease deposits to build up that could constitute a fire hazard. Metal grease filter The purpose of the grease filters is to absorb grease particles which form during cooking and it must always be used, either in the external extraction or internal recycling function. Attention: the metal grease filters must be removed and washed, either by hand or in the dishwasher, every four weeks. Removing the metal grease filter First, push the metal grease filter stop backwards, then extract the filter, pulling downwards. Hand washing Soak grease filters for about one hour in hot water with a grease-loosening cleaner, then rinse off thoroughly with hot water. Refit the grease filters when they are dry. Dishwasher Place grease filters in the dishwasher. [. . . ] 62 Technical Specifications Model DD 8890 CHDD 8890 CHDD 8820 Dimensions - extractor version (in cm): Height 70-113 Width 89, 8 Depth 50 Dimensions - filter version (in cm): Height 78-122 Width 89, 8 Depth 50 Maximum absorbed power: 215 W Motor absorption: 1 x 175 W Lighting: 2 x 20 W Lengthof the cable: 150 cm Electrical connection: 220 - 240 V 68, 5-113, 4 119, 8 46 77, 2 - 123 119, 8 46 275 W 1 x 175 W 4 x 20 W 150 cm 240 V Mounting accessories included 1 chimney support 1 reduction flange Ø 125-120 mm 1 deflector 1 allen spanner (for TORX screws) 1 support bracket 6 wood-screws 5 x 45 mm (for wall mounting) 6 wall plugs Ø 8 mm (for wall mounting) 2 metal screws 2, 9 x 6, 5 (for chimney flue mounting) DD 8890 - CHDD 8890 only 4 metal screws 3, 5 x 9, 5 (to affix the deflector to the support) CHDD 8820 only 4 metal screws 2, 9 x 6, 5 (2 for chimney flue mounting + to affix the deflector to the support) 63 Electrical connection (not for UK) Safety warnings for the electrician Before connecting the appliance to the power supply, check that the voltage indicated on the rating plate corresponds to the mains power supply available. Appliances fitted with a plug can be connected to any standard power socket within easy access. Should it be necessary to provide a fixed connection, the hood must only be installed by an electrician authorised by the local electricity board. When installing, an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX CHDD8890-A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX CHDD8890-A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag