User manual AEG-ELECTROLUX DI9611-M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX DI9611-M. We hope that this AEG-ELECTROLUX DI9611-M user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX DI9611-M.


Mode d'emploi AEG-ELECTROLUX DI9611-M
Download
Manual abstract: user guide AEG-ELECTROLUX DI9611-M

Detailed instructions for use are in the User's Guide.

[. . . ] gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air. USE · The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. · Never use the hood for purposes other than for which it has ben designed. · Never leave high naked flames under the hood when it is in operation. [. . . ] · Tighten the two screws and fasten the other two screws provided with the hood. Before tightening the screws completely it is possible to adjust the frame by turning it. Make sure that the screws do not come out of their seats in the slotted holes. · The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device. On completion, check that the base is stable, even if the frame is subjected to bending. · In all cases where the ceiling is not strong enough at the suspension point, the installer must provide strengthening using suitable plates and backing pieces anchored to the structurally sound parts. 1 1 2 2 EN 2 22 Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 125mm, the choice of which is left to the installer. To install a ø 150 · To install the dumper 10a. · Fix the pipe in position using sufficient pipe clamps (not supplied). To install a ø 125 · To install a ø 125 mm air exhaust connection, insert the reducer flange 9 on the dumper 10a. · To install the Adapting ring 10b. · Fix the pipe in position using sufficient pipe clamps (not supplied). · Remove any activated charcoal filters. ø 150 25 10a ø 125 25 10b 9 10a Recirculation version air outlet · Fix the connection 15 to the frame using the 4 screws provided. · Fix the flange 10 to the lower opening of the connection 15. · Connect the hood air outlet to the flange in the lower part of the junction using a rigid or flexible ø 150 10 tube (by installer's choice). 15 EN 2 23 ELECTRICAL CONNECTION · Connect the Hood to the mains power supply, inserting a twopole cut-out switch with contact aperture of at least 3 mm along the line. · Pull the Comfort Panel to open it, ensure that the supply cable connector is properly inserted into the Suction device socket · Join the connectors. · Install the odour filter and the charcoal filter in case the hood is to be used in recycling version. · Install the grease filter again, and successively the suction panel. Lux Cmd Flue assembly - Mounting the hood body · Position the upper chimney section and fix the upper part to the frame using the 2 screws 12c (2, 9 x 6, 5) provided. · Similarly, position the lower chimney section and fix the lower part to the frame using the 2 screws 12c (2, 9 x 6, 5) provided. The charcoal filter is triggered after 200 working hours. This indication shows only when the motor is switched off. This kind of indication should be activated by following the procedures explained in the maintenance section of the active charcoal filter. Reset alarm: Please switch the motor off and press key D for about 3 seconds until the display turns off. F Shows the remaining time before the hood shuts down (countdown). [. . . ] · Put the metal grease filters in their seats. · Close the comfort panels. EN 2 27 Lighting system LIGHT REPLACEMENT Upper Halogen Lights ( 20 W ) · Remove the snap-on lamp cover by levering it from under the metal ring, supporting it with one hand · Remove the halogen lamp from the lamp holder by pulling gently. · Replace the lamp with a new one of the same type, making sure that you insert the two pins properly into the housings on the lamp holder. · Replace the snap-on lamp cover Lower Halogen Lights (20 W ) · Find the cut side of the snap-on cover ring by pressing gently toward the centre of the spot light; it will be released. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX DI9611-M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX DI9611-M will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag