Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EFC009X. We hope that this AEG-ELECTROLUX EFC009X user guide will be useful to you.
Lastmanuals help download the user guide AEG-ELECTROLUX EFC009X.
Manual abstract: user guide AEG-ELECTROLUX EFC009X
Detailed instructions for use are in the User's Guide.
[. . . ] Gebrauchsanweisung, Manuel d'utilisation
EFC 009 X
Istruzioni per l'uso, User Manual
D
F
I
UK
Contents
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Description of the appliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Mounting of grease filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] If a fire starts; Switch of the cooker hood and the heating zone; Cover the fire , Never use water.
At disposal
l Help to avoid damages even when the cooker hood should be disposed. Disconnect the power plug and cut the power cord at hood inlet. Check with the authorities for information of how to proceed for disposal.
Description of the appliance
1. Grease filters Standard accessories included: l Screws for mounting l No return valve (mounted on air outlet) l Drilling scheme l Connection ring l Deflector (Recycling version) Fig. 1
1
2
a
3
b
Mounting of grease filters
The grease filters are supplied apart inside an apposite package; follow these instructions for mounting: l Fit the pins of the filter on the slots of the grease filter housing, then use the handles of the filter to lock them. l Pull the handles backwards to loosen the filter. 1).
Function
The hood may be used as follows: - Exhausting version - Recycling version
A - Ø 150 mm
Exhausting version
The air is vented outdoors by a 150 mm duct which must be connected to connecting ring with no return valve A on top of the motor package (Fig. The hood cannot be connected to flues of other appliances that run on energy sources other than electricity. Please, keep to the provisions of official directives regarding the question of fumes discharge.
Fig. 2
Recycling version
The air is filtered through a carbon filter and recirculated into the room through the top sides of the chimney (Fig. This version is used when there is no exhaust duct for venting outdoors or when it is impossible to install one. 3
Special accessories
Active carbon filter
When the hood is used in recirculation mode an active carbon filter should be used. Order by the retailer PNC 942 120 182
Installation
Unpacking
Check that the cooker hood has no damages. Transportation damages should immediately be reported to the one responsible for the transport Damages, faults and eventually missing details should immediately be reported to the seller. Take care of the packing material so that small children cannot play with it.
Placement
The hood is to be mounted hanging from the roof. When installed, the hood must be not less than 65 cm. 4
Min 65 cm Min 75 cm
Electrical connection
The hood has a power cord with moulded plug with earth connection to be connected to a wall outlet of 230 V. The power outlet should be pre-mounted in such a way that the power cord is invisible when the hood is fully mounted. The power cord length is 1, 25 m.
As it is then hard to disconnect the power plug for cleaning and service, an easy accessible two pole switch should be fitted. The switch should conform to regulations with an opening distance between contacts of not less than 3 mm.
37
Mounting of hood
First set the telescopic support structure on the right direction and drill as indicated on the drilling scheme supplied with the hood. [. . . ] Generally, these must be cleaned after 40 hours of use. Read the maintenance instructions provided for the grease filters.
41
Carbon filter saturation led
The LED marked C indicates carbon filter needs to be replaced. This must be done after approximately 160 hours of use. Read the instructions provided for replacing the carbon filter.
Correct ventilation
To have the cooker hood working correctly the windows in the kitchen should be closed. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EFC009X
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.