User manual AEG-ELECTROLUX EFC12011K

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EFC12011K. We hope that this AEG-ELECTROLUX EFC12011K user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX EFC12011K.


Mode d'emploi AEG-ELECTROLUX EFC12011K
Download
Manual abstract: user guide AEG-ELECTROLUX EFC12011K

Detailed instructions for use are in the User's Guide.

[. . . ] · Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. · The hood should not be used by children or persons not instructed in its correct use. MAINTENANCE · Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. · Clean and/or replace the Filters after the specified time period. [. . . ] · Place bracket 7. 2. 1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line. · Mark the wall at the centres of the holes in the bracket. · Place bracket 7. 2. 1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line. · Mark the wall at the centres of the holes in the bracket. · Mark a reference point as indicated at 116 mm from the vertical reference line and 320 mm above the horizontal reference line. · Repeat this operation on the other side. · Drill ø 8 mm holes at all the centre points marked. · Insert the wall plugs 11 in the holes. · Fix the lower bracket 7. 2. 1 using the 12a screws (4, 2 x 44, 4) supplied. · Fix the upper bracket 7. 2. 1 and the air outlet connection support 7. 3 together using the 2 screws 12a (4, 2 x 44, 4) supplied. · Insert the two screws 12a (4, 2 x 44, 4) supplied in the hood body fixing holes, leaving a gap of 5-6 mm between the wall and the head of the screw. GB X 7. 2. 1 6 Mounting the hood body · Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points. (Activation and Reset; check the Maintenance-paragraph) GB 9 MAINTENANCE Grease filters CLEANING METAL SELF- SUPPORTING GREASE FILTERS Alarm signal reset · Switch off the lights and extractor motor. · Press button T3 for at least 3 seconds, until the leds start to flash. Cleaning the filters · The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher. · Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time. · Wash the filters, taking care not to bend them. · When refitting the filters, make sure that the handle is visible on the outside. Activated charcoal filter (Recirculation version) REPLACING THE ACTIVATED CHARCOAL FILTER Alarm signal activation · In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date. Turn the Lights and the suction Motor off. · Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply. · Restore the connection by pressing and holding T1. All five LEDs are turned on · Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation: LED flashes twice - Activated charcoal filter saturation alarm ENABLED LED flashes once - Activated charcoal filter saturation alarm DISABLED GB 10 · The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes or at least every 4 months. [. . . ] Replacing the Filter · Remove the metal grease filters · Remove the saturated activated carbon filter by releasing the fixing hooks · Fit the new filter by hooking it into its seating · Replace the metal grease filters. Lighting LIGHT REPLACEMENT 20 W halogen light. · Remove the 2 Screws fixing the Lighting support, and pull it out of from the Hood. · Extract the Lamp from the Support. · Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EFC12011K

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EFC12011K will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag