User manual AEG-ELECTROLUX EFC6540X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EFC6540X. We hope that this AEG-ELECTROLUX EFC6540X user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX EFC6540X.


Mode d'emploi AEG-ELECTROLUX EFC6540X
Download

You may also download the following manuals related to this product:

   AEG-ELECTROLUX EFC6540X (678 ko)

Manual abstract: user guide AEG-ELECTROLUX EFC6540X

Detailed instructions for use are in the User's Guide.

[. . . ] USE · The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. · Never use the hood for purposes other than for which it has ben designed. · Never leave high naked flames under the hood when it is in operation. · Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides. [. . . ] · Hook the hood body onto the screws 12a · Fully tighten support screws 12a · Adjust screws Vr to level the hood body. Vr 12a Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer. · To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. · Fix the pipe in position using sufficient pipe clamps (not supplied). · Remove any activated charcoal filters. ø 150 9 ø 120 RECIRCULATION VERSION AIR OUTLET · Put connection 15 into the connection support 7. 3. · Insert the connection extension pieces laterally 14. 1 in connection 15. · Make sure that the outlet of the extension pieces 14. 1 is horizontally and vertically aligned with the chimney outlets. · Connect the air outlet connection 15 to the hood body outlet using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer. · Ensure that the activated charcoal filters have been inserted. 14. 1 15 ø 150 GB 7 ELECTRICAL CONNECTION · Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. · Remove the grease filters and verify that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Enlever les filtres à graisse et s'assurer que le connecteur Flue assembly Upper exhaust flue · Slightly widen the two sides of the upper flue and hook them behind the brackets 7. 2. 1, making sure that they are well seated. · Secure the sides to the brackets using the 4 screws 12c (2, 9 x 9, 5) supplied. · Make sure that the outlet of the extensions pieces is aligned with the chimney outlets. Lower exhaust flue · Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated. · Fix the lower part laterally to the hood body using the 2 screws 12c (2, 9 x 9, 5) supplied. 7. 2. 1 12c 2. 1 2 2. 2 12c GB 8 USE Control Panel The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button. S1 L T1 T2 T3 T4 KEY L T1 T2 T3 T4 LED 0/1 Light 0/1 Motor Speed Speed Speed on on on Fixed Flashing S1 Led Fixed Flashing FUNCTIONS Turns lighting on and off. When pressed for about 1 seconds the motor is switched off. Suitable for the strongest cooking vapours and odours. The function becomes active when the button is pushed for about 2 seconds. After 10 minutes of functioning it turns off automatically. This function can be interrupted by means of pressing any of the buttons. Indicates that the Metal grease filters saturation alarm has been triggered, and the filters need to be washed. The alarm is triggered after 100 working hours. (Reset; check the Maintenance-paragraph) indicates that the activated charcoal odour filter saturation alarm has been triggered, and the filter has to be replaced; the metal grease filters must also be washed. The activated charcoal odour filter is triggered after 200 working hours. [. . . ] · Replace the Support, fixing it in place with the two Screws removed as above. GB 11 This appliance conforms to European Low Voltage Directive 73/23/CEE governing electrical safety, European Directive 89/ 336/CEE on Electromagnetic Compatibility and Directive 93/68/CEE regarding CE Marking. Este aparato es conforme con la normativa europea sobre baja tensión C. E. E. 73/23 correspondiente a la seguridad eléctrica y a las normativas europeas : C. E. E. 89/336 sobre la compatibilidad electromagnética y C. E. E. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EFC6540X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EFC6540X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag