User manual AEG-ELECTROLUX EFC9447U/S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EFC9447U/S. We hope that this AEG-ELECTROLUX EFC9447U/S user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX EFC9447U/S.


Mode d'emploi AEG-ELECTROLUX EFC9447U/S
Download
Manual abstract: user guide AEG-ELECTROLUX EFC9447U/S

Detailed instructions for use are in the User's Guide.

[. . . ] Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. The hood should not be used by children or persons not instructed in its correct use. MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. Clean and/or replace the Filters after the specified time period. [. . . ] Clean the hood using a damp cloth and a neutral liquid detergent. 650 mm min. EN 5 5 CHARACTERISTICS Dimensions 240 18 min. 765 100 598 - 698 - 898 210 150 490 205 650 min. Components Ref. Q. ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower, Filters 2 1 Telescopic Chimney comprising: 2. 1 1 Upper Section 2. 2 1 Lower Section 9 1 Reducer Flange 150-120 mm 15 1 Air Outlet Connection Ref. Q. ty Installation Components 7. 1 2 Hood Body Fixing Brackets 7. 2. 1 2 Upper Chimney Section Fixing Brackets 11 8 Wall Plugs 12a 8 Screws 4. 2 x 44, 4 12c 6 Screws 2. 9 x 9. 5 12d 2 Screws M4 x 25 Q. ty Documentation 1 Instruction Manual 15 12a 7. 2. 1 11 9 12c 2. 1 2 2. 2 12c 12c 12a 11 7. 1 1 12d EN 6 6 INSTALLATION Wall drilling and bracket fixing 12 650 min. Wall marking: Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. Draw a horizontal line at 650 mm above the hob for installation without the back panel, or at height H (H=height of the visible part of the panel) for installation with the back panel. Place bracket 7. 2. 1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line. Mark the wall at the centres of the holes in the bracket. Place bracket 7. 2. 1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line. Mark the wall at the centres of the holes in the bracket. Place bracket 7. 1 as shown 95 mm from the vertical reference line and 210 mm above the horizontal reference line. Fix the lower part laterally to the hood body using the 2 screws 12c (2, 9 x 9, 5) supplied. Make sure that the air outlet connection is aligned with the chimney outlets. 2. 2 2 2. 1 12c 12c 12c EN 9 9 USE 3 12 01 01 V L M L M V Light Motor Speed Switches the lighting system on and off Switches the extractor motor on and off Sets the operating speed of the extractor: 1. Low speed, used for a continuous and silent air change in the presence of light cooking vapour. Medium speed, suitable for most operating conditions given the optimum treated air flow/noise level ratio. Maximum speed, used for eliminating the highest cooking vapour emission, including long periods. EN 1 10 0 MAINTENANCE Grease filters CLEANING METAL SELF- SUPPORTING GREASE FILTERS The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher. Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time. Wash the filters, taking care not to bend them. When refitting the filters, make sure that the handle is visible on the outside. Activated charcoal filter (Recirculation version) These filters are not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently with heavy usage. REPLACING THE ACTIVATED CHARCOAL FILTER Remove the metal grease filters Remove the saturated activated charcoal filter as shown (A). Replace the metal grease filters. B A Lighting LIGHT REPLACEMENT 40 W incandescent light. [. . . ] Replace the metal grease filters. B A Lighting LIGHT REPLACEMENT 40 W incandescent light. Unscrew the bulbs and replace them with new ones having the same characteristics. Replace the metal grease filters. EN 1 11 1 The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EFC9447U/S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EFC9447U/S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag