If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EFC9500X-T. We hope that this AEG-ELECTROLUX EFC9500X-T user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX EFC9500X-T.


Mode d'emploi AEG-ELECTROLUX EFC9500X-T
Download
Manual abstract: user guide AEG-ELECTROLUX EFC9500X-T

Detailed instructions for use are in the User's Guide.

[. . . ] · For Class I appliances, check that the domestic power supply guarantees adequate earthing. Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible. · Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc. ). [. . . ] · Draw a horizontal line at 650 mm above the hob. · Place bracket 7. 2. 1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line. · Mark the wall at the centres of the holes in the bracket. · Place bracket 7. 2. 1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line. · Mark the wall at the centres of the holes in the bracket. · Mark a reference point as indicated at 116 mm from the vertical reference line and 306 mm above the horizontal reference line. · Repeat this operation on the other side. · Drill ø 8 mm holes at all the centre points marked. · Insert the wall plugs 11 in the holes. · Fix the lower bracket 7. 2. 1 using the 12a screws (4, 2 x 44, 4) supplied. · Fix the upper bracket 7. 2. 1 and the air outlet connection support 7. 3 together using the 2 screws 12a (4, 2 x 44, 4) supplied. · Insert the two screws 12a (4, 2 x 44, 4) supplied in the hood body fixing holes, leaving a gap of 56 mm between the wall and the head of the screw. GB 650 min. 306 X 7. 2. 1 7 Mounting the hood body · Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points. · Hook the hood body onto the screws 12a · Fully tighten support screws 12a · Adjust screws Vr to level the hood body. Vr 12a Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer. · To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. · Fix the pipe in position using sufficient pipe clamps (not supplied). ø 150 ø 120 · Remove any activated charcoal filters. 9 RECIRCULATION VERSION AIR OUTLET · Put connection 15 into the connection support 7. 3. · Insert the connection extension pieces laterally 14. 1 in connection 15. · Make sure that the outlet of the extension pieces 14. 1 is horizontally and vertically aligned with the chimney outlets. · Connect the air outlet connection 15 to the hood body outlet using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer. · Ensure that the activated charcoal filters have been inserted. [. . . ] · When refitting the filters, make sure that the handle is visible on the outside. Activated charcoal filter (Recirculation version) REPLACING THE ACTIVATED CHARCOAL FILTER · The filter is not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently for particularly heavy usage. · Remove the metal grease filters · Remove the saturated activated carbon filter by releasing the fixing hooks · Fit the new filter by hooking it into its seating · Replace the metal grease filters. Lighting LIGHT REPLACEMENT 20 W halogen light. · Remove the snap-on lamp cover by levering it from under the metal ring, supporting it with one hand. · Extract the Lamp from the Support. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EFC9500X-T

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EFC9500X-T will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag