User manual AEG-ELECTROLUX EFC9541X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EFC9541X. We hope that this AEG-ELECTROLUX EFC9541X user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX EFC9541X.


Mode d'emploi AEG-ELECTROLUX EFC9541X
Download
Manual abstract: user guide AEG-ELECTROLUX EFC9541X

Detailed instructions for use are in the User's Guide.

[. . . ] · If the extractor is used in conjunction with non-electrical appliances (e. g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air. USE · · · · The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. [. . . ] If you wish to adjust the height of the frame, proceed as follows: · Unfasten the eight metric screws joining the two columns, located at the sides of the frame. · Adjust the frame to the height required, then replace all the screws removed as above. · Insert the upper chimney stack from above, and leave it running free on the frame. · Lift up the frame, fit the frame slots onto the screws up to the slot end positions. · Tighten the two screws and fasten the other two screws provided with the hood. Before tightening the screws completely it is possible to adjust the frame by turning it. Make sure that the screws do not come out of their seats in the slotted holes. · The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device. On completion, check that the base is stable, even if the frame is subjected to bending. · In all cases where the ceiling is not strong enough at the suspension point, the installer must provide strengthening using suitable plates and backing pieces anchored to the structurally sound parts. 1 1 2 2 Ducted version air exhaust system Connection When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer. · To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. · Fix the pipe using the pipe clamps 25 provided. · Remove any activated charcoal filters. ø 150 ø 120 25 25 9 EN 8 8 Recirculation version air outlet · Fix the connection 15 to the frame using the 4 screws provided. · Fix the flange 10 to the lower opening of the connection 15. · Connect the hood air outlet to the flange in the lower part of the junction using a rigid or flexible ø 150 tube (by installer's choice). 10 15 Flue assembly - Mounting the hood body · Position the upper chimney section and fix the upper part to the frame using the 2 screws 12c (2, 9 x 6, 5) provided. · Similarly, position the lower chimney section and fix the lower part to the frame using the 2 screws 12c (2, 9 x 6, 5) provided. 12c 12c Before fixing the hood body to the frame: · Remove the grease filters from the hood body. · Remove any activated charcoal filters. · From below, use the 4 screws 12f (M6 x 10)provided to fix the hood body to the frame. 12f ELECTRICAL CONNECTION · Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. · Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. · Connect the control connector Cmd. · Connect the lights connector Lux. · Place the connectors in the junction box 24 and close it using the 2 screws 12e (2, 9 x 9, 5) provided. [. . . ] Alarm signal activation · In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date. Turn the Lights and the suction Motor off. · Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply. · Restore the connection by pressing and holding T1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EFC9541X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EFC9541X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag