If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EFC9551X/A. We hope that this AEG-ELECTROLUX EFC9551X/A user guide will be useful to you.
Lastmanuals help download the user guide AEG-ELECTROLUX EFC9551X/A.
Manual abstract: user guide AEG-ELECTROLUX EFC9551X/A
Detailed instructions for use are in the User's Guide.
[. . . ] USE · The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. · Never use the hood for purposes other than for which it has ben designed. · Never leave high naked flames under the hood when it is in operation. · Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides. [. . . ] · Remove any activated charcoal filters.
ø 150
9
ø 120
RECIRCULATION VERSION AIR OUTLET · Put connection 15 into the connection support 7. 3. · Insert the connection extension pieces laterally 14. 1 in connection 15. · Make sure that the outlet of the extension pieces 14. 1 is horizontally and vertically aligned with the chimney outlets. · Connect the air outlet connection 15 to the hood body outlet using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer. · Ensure that the activated charcoal filters have been inserted.
15
14. 1
ø 150
EN
6 6
ELECTRICAL CONNECTION · Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. · Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.
Flue assembly
Upper exhaust flue · Slightly widen the two sides of the upper flue and hook them behind the brackets 7. 2. 1, making sure that they are well seated. · Secure the sides to the brackets using the 4 screws 12c (2, 9 x 9, 5) supplied. · Make sure that the outlet of the extensions pieces is aligned with the chimney outlets. Lower exhaust flue · Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated. · Fix the lower part laterally to the hood body using the 2 screws 12c (2, 9 x 9, 5) supplied.
7. 2. 1 12c
2. 1 2 2. 2
12c
EN
7 7
USE
L T1 T2 T3 T4 T5 F
The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button .
Touch control
Basic functions Dual Function
When briefly pressed it switches the lighting system on and off.
Indicator lights
Touch control unlit Lights off Lights off Lights on
L
When pressed for 2 seconds it switches the electro- Touch control unlit luminescent lighting on and off. This function is independent from the basic functions of the control uTouch control lit nit. It is therefore possible to switch on simultaneously the hood lighting and the electroluminescent lighting. During the electroluminescent lighting mode Touch control unlit the touch control is unlit.
T1 T2 T3
When pressed the motor is stopped, regardless of the speed it is set to. When pressed the motor is set to the first speed By a brief pressing the motor is set to the second speed. By pressing the touch control for approximately 2 seconds the Delay function is enabled, i. e delayed shutdown of the appliance ensuring a complete elimination of the residual odours. This function can be activated at OFF-position and at 1°, 2° and 3°speeds. It can be stopped in advance by pressing any of the touch controls (T) with the exception of T3. The Delay function works according to the following scheme: 1°speed / OFF = 20 minuets 2°speed = 15 minutes 3°speed = 5 minutes When pressed the motor is set to the third speed
Touch control lit Touch control unlit
Electroluminescent lighting on Motor on Motor off
Touch control lit Touch control lit Flashing touch control Second speed on Delay function on
T4
Touch control lit
EN
8 8
Touch control
Basic functions
Indicator lights
T5
F
When pressed the motor is set to the intensive speed timed to 5 minutes. At the end of 5 minutes of intensive speed the hood starts again at the speed it was set Touch control lit to previously. In case the hood is set to the intensive speed directly from OFF-state it will then start from the first speed after 5 minutes of intensive speed. Touch control lit Metal grease filters satuWhen pressed for 4 seconds it resets the filter alarm ration alarm. Metal grease signal indicated by flashing of the touch control T1. [. . . ] · Press the touch control F for at least 4 seconds, until the touch control T1 flashes. Replace the Filter · Pull the Comfort Panel to open it. · Remove the metal grease filters. · Remove the saturated charcoal filter, turning the fasteners provided. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EFC9551X/A
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.