User manual AEG-ELECTROLUX EFG692B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EFG692B. We hope that this AEG-ELECTROLUX EFG692B user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX EFG692B.


Mode d'emploi AEG-ELECTROLUX EFG692B
Download
Manual abstract: user guide AEG-ELECTROLUX EFG692B

Detailed instructions for use are in the User's Guide.

[. . . ] 3. 7 - Never leave frying pans unattended during use as overheated fat and oil may catch fire. 3. 8 - Before carrying out any kind of maintenance or cleaning, disconnect the hood from the mains supply. 3. 9 - If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this 2 - Cut a hole in the upper part of the canopy, where you prefer to have the air-outlet, according to the diameter of the duct and following the instructions of the table below. [. . . ] 4 - Insert the upper part of the hood through the hole cut in the underside of the canopy (ensuring that the butterfly catches S are loose enough so that they spring open) and hook onto the base of the canopy. 5 - Access to the securing screws in the butterfly brackets is through two holes in the lower casing as illustrated in fig. Turn the screws clockwise until the hood is firmly attached to the cabinet. 4. 2 - Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED 1 - It is imperative that the safety measures contained in paragraphs 3. 2, 3. 3, 3. 4 are strictly observed. 2 - Before connection to the mains supply check that the circuitry is sound. After the connection has been tested switch on the mains supply and check that the worktop illumination lamp and three fan speeds function correctly. Part 2 OPERATION AND 4. 3 - Ducting or recirculation fitting 1 - Ducting fitting: a - The cooker hood can be ducted to the outside using either a fire retardant rigid or flexible ducting of 100 or 120 mm diameter. The choice is left to the installer (fig. b - The ducting spigot R supplied has an air outlet of 100 mm diameter. To adapt the spigot to 120 mm diameter cut along the slot as illustrated in fig. c - Connect the ducting spigot R to the cooker hood by placing the spigot over the rectangular outlet on the top of the upper assembly and secure the spigot using two of the screws provided as illustrated in fig. Position 3, top speed, should be selected when frying or cooking food with strong odours, even for sustained periods. 3 - MAINTENANCE Regular maintenance and cleaning will ensure good performance and reliabilty, while extending the working life of the hood. Special attention should be taken to ensure that the grease filters and charcoal filters (when the hood is used in the recirculation mode) are cleaned and replaced as recommended. 2 - Replacement: a - To remove the charcoal filter first open the lower grille or remove the metal filters as instructed in paragraph 3. 1 2a and 3. 1 2b. b - Remove the separating plate if your cooker hood is in 54 cm and with metal filters (fig. c - Remove the charcoal filter by pressing inwardly on the two catches while pushing the filter backwards and down as illustrated in fig. d - The charcoal filter should be replaced by reversing the operation. 3. 1 - Thin synthetic filter 1 - Cleaning: This filter cannot be washed and should be replaced every two months. If the filter is provided with a saturation indicator, replace when the violet colour of the dots which are visible from the outside is spread over the whole surface of the filter. 2 - Replacing: The filter is located on the reverse side of the metal grille. To replace it first open the grille as illustrated in fig. Replace by reversing the operations. 3. 4 - Worktop illumination The hood may be fitted with a 15W fluorescent strip lamp or with two 40W lamps. [. . . ] To replace them proceed as follows: a - Remove one of the two plastic covers T by loosening the fixing screw; the glass diffuser is retained in position by the metal retaining lug L (fig. 14); b - Slide the diffuser towards the side where the plastic cover T has been removed until the opposite end is free (arrow 1); Pull the glass diffuser down slightly (arrow 2) and then move it back in the opposite direction until the lighting diffuser can be released from the retaining lugs L (arrow 3) (fig. 15); c - When replacing the fluorescent strip lamp an identical replacement must be fitted rotating it trough 90 degrees; replace the lamps fitted in the lampholders with identical replacements; d - Refit the glass diffuser by reversing the operations. 3. 2 - Metal grease filters 1 - Cleaning The metal grease filters replace the metal grille completely and should be cleaned every two months with normal usage. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EFG692B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EFG692B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag