User manual AEG-ELECTROLUX EHT6432W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EHT6432W. We hope that this AEG-ELECTROLUX EHT6432W user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX EHT6432W.


Mode d'emploi AEG-ELECTROLUX EHT6432W
Download
Manual abstract: user guide AEG-ELECTROLUX EHT6432W

Detailed instructions for use are in the User's Guide.

[. . . ] user manual GB AUS ERFAHRUNG GUT Gas hob EHT 6432 2 electrolux electrolux 3 Welcome to the world of Electrolux Thank you for choosing a first class product from Electrolux, which hopefully will provide you with lots of pleasure in the future. The Electrolux ambition is to offer a wide variety of quality products that make your life more comfortable. You find some examples on the cover in this manual. Please take a few minutes to study this manual so that you can take advantage of the benefits of your new machine. [. . . ] after cleaning. electrolux 13 Instructions for the Installer Engineer technical data OVERALL DIMENSIONS Width: Depth: CUT OUT DIMENSIONS Width: Depth: Thickness APPLIANCE CLASS 3 580 mm 510 mm 550 mm 470 mm 30 mm SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230 V ~ 50 Hz supply, 3 core flexible cable HEAT INPUT Rear Left Burner (semi rapid) Front Left Burner (rapid) Rear Right Burner (semi rapid) Front Right Burner (auxiliary) 1. 9 kW 2. 9 kW Natural gas 2. 7 kW Liquid gas 1. 9 kW 1. 0 kW APPLIANCE CATEGORY II2H3+ GAS SUPPLY Natural gas G20-2H-20 mbar Table 1 : By-pass diameters Burner Ø By-pass in 1/100 of mm 28 32 42 Auxiliary Semi-rapid Rapid 14 electrolux Table 2 : Injectors TYPE OF GAS BURNER INJECTORS 1/100 mm NORMAL POWER kW REDUCED POWER kW NORMAL POWER 3 m /h g/h G30 FEEDING PRESSURE g/h G31 mbar NATURAL GAS Rapid Semi-rapid Auxiliary Rapid Semi-rapid Auxiliary 119 96 70 86 71 50 2, 9 1, 9 1, 0 2, 7 1, 9 1, 0 0, 75 0, 45 0, 33 0, 75 0, 45 0, 33 0, 276 0, 181 0, 09 - - - 20 LIQUID GAS 196 192 138 136 73 71 28-30 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I. S. 813 Current Editions and the ETCI Rules for Electrical Installations. Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. 6891 Current Editions. Provision for ventilation The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic Gas Installation I. S. 813 Current Editions Table Four. electrolux 15 Location The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room. Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm between the rear edge of the hob and the wall. A minimum distance of 100 mm must be left between the side edges of the hob and any adjacent cabinets or walls. The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm If it is fitted below 400 mm a space of 50 mm must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm. For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I. S 813 Current Edition Section 7- Permitted Locations of Appliance. CLEARANCES REQUIRED WHEN FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE CLEARANCES REQUIRED WHEN FITTING THE GAS HOB WITH A COOKER HOOD ABOVE 700 mm FO 0812 FO 0813 16 electrolux Instruction for the Installer The following instructions about installation and maintenance must be carried out by qualified personnel in compliance with the regulation in force. The appliance must be electrically disconnected before all interventions. If any electric supply to the appliance is required to carry out the work, ensure all the necessary precautions are followed. The side walls of the unit in which the hob is going to be installed, must not exceed the height of the working top. Avoid installing the appliance in the proximity of inflammable materials (e. g. curtains, tea towels etc. ). THE MANUFACTURER WILL NOT ACCEPT LIABILITY, SHOULD ANY OF THE OTHER SAFETY INSTRUCTIONS INCORPORATED IN THIS BOOKLET OR THE REGULATION IN FORCE BE IGNORED. electrolux 17 Installation IMPORTANT This hob must be installed by a competent person to the relevant Gas Standards. [. . . ] Any repair work which needs to be carried out should be done with the utmost care and attention. For this reason we recommend that for any problem you contact the dealer who sold it to you, or our nearest authorized Service Centre, specifying the nature of the problem, the appliance model (Mod. ), the product number (Prod. No. ) marked on the identification plate. Original spareparts, certified by the product manufacturer and carrying this symbol are only available at our Service Centre and authorized spareparts shops. 30 electrolux Standard Guarantee Conditions We, Electrolux, undertake that if within 12 months of the date of the purchase this Electrolux appliance or any part thereof is proved to be defective by reason only of faulty workmanship or materials, we will, at our option repair or replace the same FREE OF CHARGE for labour, materials or carriage on condition that: ·The appliance has been correctly installed and used only on the gas and electricity supply stated on the rating plate. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EHT6432W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EHT6432W will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag