User manual AEG-ELECTROLUX EXS09HC1WE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EXS09HC1WE. We hope that this AEG-ELECTROLUX EXS09HC1WE user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX EXS09HC1WE.


Mode d'emploi AEG-ELECTROLUX EXS09HC1WE
Download
Manual abstract: user guide AEG-ELECTROLUX EXS09HC1WE

Detailed instructions for use are in the User's Guide.

[. . . ] Website: www. mideaaircon. com Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORIZED SERVICE PERSONNEL. MODELS: EL-KF20GW/N2Y-A(B) EL-KF36GW/N2Y-A(B) EL-KF61GW/N2Y-A(B) EL-KFR20GW/N1Y-A(B) EL-KF20GW/Y-A(B) EL-KF32GW/Y-A(B) EL-KF50GW/Y-A(B) EL-KF70GW/Y-A(B) EL-KF90GW/SY-A(B) AU-KF70GW/Y-A(B) EL1-KF20GW/Y-A(B) EL1-KF32GW/Y-A(B) EL1-KF26GW/N2Y-A(B) EL-KT3F53GW/Y-T2 EL-KT3F70GW/Y-T2 SEL-KF20GW/Y-A(B) SEL-KF32GW/Y-A(B) SEL-KF61GW/Y-A(B) SEL1-KF26GW/Y-A(B) EL-KFR20GW/N2Y-A(B) EL-KFR36GW/N2Y-A(B) EL-KFR61GW/N2Y-A(B) EL-KFR26GW/N1Y-A(B) EL-KFR20GW/Y-A(B) EL-KFR32GW/Y-A(B) EL-KFR50GW/Y-A(B) EL-KFR70GW/Y-A(B) EL-KFR90GW/SY-A(B) AU-KFR70GW/Y-A(B) EL1-KFR20GW/Y-A(B) EL1-KFR32GW/Y-A(B) EL1-KFR26GW/N2Y-A(B) EL-KT3F53GW/Y-T1 EL-KT3F70GW/Y-T1 SEL-KFR20GW/Y-A(B) SEL-KFR32GW/Y-A(B) SEL-KFR61GW/Y-A(B) SEL1-KFR26GW/Y-A(B) EL-KF26GW/N2Y-A(B) EL-KF50GW/N2Y-A(B) EL-KF70GW/N2Y-A(B) EL-KFR36GW/N1Y-A(B) EL-KF26GW/Y-A(B) EL-KF36GW/Y-A(B) EL-KF61GW/Y-A(B) EL-KF90GW/Y-A(B) AU-KF61GW/Y-A(B) AU-KF85GW/Y-A(B) EL1-KF26GW/Y-A(B) EL1-KF20GW/N2Y-A(B) EL1-KF35GW/N2Y-A(B) EL-KT3FR53GW/Y-T1 EL-KT3FR70GW/Y-T1 SEL-KF26GW/Y-A(B) SEL-KF53GW/Y-A(B) SEL-KF70GW/Y-A(B) SEL1-KF36GW/Y-A(B) SEL-KFR26GW/Y-A(B) SEL-KFR53GW/Y-A(B) SEL-KFR70GW/Y-A(B) SEL1-KFR36GW/Y-A(B) EL-KFR26GW/Y-A(B) EL-KFR36GW/Y-A(B) EL-KFR61GW/Y-A(B) EL-KFR90GW/Y-A(B) AU-KFR61GW/Y-A(B) AU-KFR85GW/Y-A(B) EL1-KFR26GW/Y-A(B) EL1-KFR20GW/N2Y-A(B) EL1-KFR35GW/N2Y-A(B) EL-KFR26GW/N2Y-A(B) EL-KFR50GW/N2Y-A(B) EL-KFR70GW/N2Y-A(B) 0 GD Midea Refrigerant Equipment Co. Ltd Service manual for Electrolux split Series CONTENTS 1. PREFACE 1. 1 SAFETY PRECAUTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1. 2 INSULATION RESISTANCE TEST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1. 3 FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1. 4 CONTROL LOCATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1. 5 OUTSIDE DIMENSIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. [. . . ] 2. 6. 2. 3 In cases where the outdoor unit is installed above the indoor unit perform the following. Tape the piping and connecting cable from down to up. Secure the taped piping along the exterior wall. Form a trap to prevent water entering the room. Fix the piping onto the wall by saddle or equivalent. 2. 6. 1. 3 Drain piping The drain hose should point downward for easy drain flow. Do not make drain piping similar to diagrams shown below. 2. 6. 2 Form the piping 2. 6. 2. 1 Form the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with narrow vinyl tape and wide vinyl tape. If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appropriately. 14 GD Midea Refrigerant Equipment Co. Ltd Service manual for Electrolux split Series 2. 7 AIR PURGING 2. 7. 1 Air purging Air and moisture remaining in the refrigerant system have undesirable effects as indicated below. Cooling (or heating if applicable) efficiency drops. Moisture in the refrigerant circuit may freeze and block capillary tubing. Water may lead to corrosion of parts in the refrigeration system. Therefore, the indoor unit and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any non-condensable substance and moisture from the system. 2. 7. 2 Air purging with vacuum pump 2. 7. 2. 1 Preparation Check that each tube (both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage. 2. 7. 2. 2 Leak test Connect the manifold set (with pressure gauges) and dry nitrogen gas cylinder to this service port with charge hoses. CAUTION Be sure to use a manifold set for air purging. If it is not available, use a stop valve for this purpose. The "Hi" knob of the manifold valve must always be kept closed. Pressurizes the system to no more than 1MPa (Approx. [. . . ] Correct the installation if not correct. Correct it. It's normal if the humidity in the room is over 85%. Correct if the commucication wire is not shielded wire or twisted with other wires. Replace if the LED is not on. 25 GD Midea Refrigerant Equipment Co. Ltd Service manual for Electrolux split Series 4 WIRING DIAGRAM 4. 1 WIRING DIAGRAM FOR INDOOR UNITS 4. 1. 1 For models: EL-KF20GW/N2Y-A(B) EL-KF20GW/Y-A(B) EL1-KF20GW/Y-A(B) EL1-KF20GW/N2Y-A(B) EL-KF26GW/N2Y-A(B) EL-KF26GW/Y-A(B) EL1-KF26GW/Y-A(B) EL1-KF26GW/N2Y-A(B) EL-KF32GW/Y-A(B) EL1-KF32GW/Y-A(B) POWER SUPPLY BROWN INDOOR MOTOR Y/G BLUE BLACK 135 135 CN6 CN11 321 321 CN4 1 23 45 12345 CN12 21 21 CN2 21 21 CN3 RED C N5 P IP E TE MP ER AT UR E SE NS OR STEP MOT OR RO OM T EM P ER AT UR E S EN S OR 8 7 6 5 4 32 1 COMPRESSOR RELAY C N1 5 CN1 1 1 3 3 Y/G 1 2(N) 3 4 INDOOR UNIT TO OUTDOOR UNI T TRANSFORMER J1 X 4. 1. 2 For models: EL-KFR20GW/N2Y-A(B) EL-KFR20GW/Y-A(B) EL-KFR20GW/N1Y-A(B) EL1-KFR20GW/Y-A(B) EL1-KFR26GW/N2Y-A(B) EL-KFR26GW/N2Y-A(B) EL-KFR26GW/Y-A(B) EL-KFR26GW/N1Y-A(B) EL1-KFR26GW/Y-A(B) EL1-KFR35GW/N2Y-A(B) EL-KFR36GW/N2Y-A(B) EL-KFR32GW/Y-A(B) EL-KFR36GW/N1Y-A(B) EL1-KFR32GW/Y-A(B) SEL1-KFR26GW/Y-A(B) ROO M T E P E R AT R E M U S ESOR N P IP E TE MP ER AT UR E SE NS OR D IS PL AY B OA RD STEP MOTOR POWER SUPP LY BROWN 1 35 1 35 CN6 BLUE BLACK CN11 COMPRESSOR RELAY 13 13 EL-KFR36GW/Y-A(B) EL1-KFR20GW/N2Y-A(B) SEL1-KFR36GW/Y-A(B) INDOOR MOTOR Y/G 321 321 CN4 1 2 3 45 12345 CN12 21 21 CN2 21 21 CN3 RED CN 5 8 7 6 5 4 3 21 YELLOW BLUE C N1 5 C N1 3_2 C N1 3_1 CN1 1 1 3 3 Y/G JX1 1 2(N) 3 4 INDOOR UNIT TO OUTDOOR UNI T TRANSFORMER 26 DIS PL A Y B A RD O GD Midea Refrigerant Equipment Co. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EXS09HC1WE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EXS09HC1WE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag