User manual AEG-ELECTROLUX EXS18GC4WE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EXS18GC4WE. We hope that this AEG-ELECTROLUX EXS18GC4WE user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX EXS18GC4WE.


Mode d'emploi AEG-ELECTROLUX EXS18GC4WE
Download
Manual abstract: user guide AEG-ELECTROLUX EXS18GC4WE

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION 2. 1 TOOLS NEEDED FOR INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. 2 ITEMS REQUIRED FOR INSTALLING THE UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. 3 INSTALLATION OF INDOOR UNIT AND OUTDOOR UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2. 4 FLARING WORK AND CONNECTION OF PIPING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2. 5 CONNECTING THE CABLE BETWEEN INDOOR UNIT AND OUTDOOR UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2. 6 CHECKING THE DRAINAGE AND FORMING THE PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2. 7 AIR PURGING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2. 8 TEST RUNNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3. TROUBLE SHOOTING GUIDE 3. 1 Refrigeration Cycle Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 3. 2 TROUBLE SHOOTING GUIDE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 4. WIRING DIAGRAM 4. 1 Wiring diagram for indoor units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 4. 2 Wiring diagram for outdoor units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5. EXPLODED VIEWS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 6 SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 7 SPARE PARTS LIST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 8 MODEL CHECK LIST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 1. [. . . ] Particularly note the relation between cable length and thickness. (Refer to page 11. ) 7) Always install a Residual Current Device (RCD) in wet or moist area. 8) The following may be caused by voltage drop. Vibration of a contactor, which will damage the contact point, fuse blowing, disturbance of the normal function of the overload. 9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active (phase) conductor. If a power plug is not to be used, provide a Circuit Breaker/Fuse between power source and the unit as shown in adjacent diagram. CAUTIONS: After confirming the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power circuit 13 GD Midea Refrigerant Equipment Co. Ltd Service manual for Electrolux split Series 2. 6 CHECKING THE DRAINAGE AND FORMING THE PIPE 2. 6. 1 Checking the drainage 2. 6. 1. 1 To remove the front panel from the indoor unit. Pull the lower left and right sides of the grille toward you and lift it up. 2. 6. 2. 2 In cases where the outdoor unit is installed below the indoor unit perform the following. Tape the piping, drain hose and connecting cable from down to up. Secure the tapped piping along the exterior wall using saddle or equivalent. 2. 6. 1. 2 To check the drainage. Pour a glass of water on the evaporator. Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. 145psi) with dry nitrogen gas and close the cylinder valve when the gauge reading reaches 1MPa (Approx. CAUTION Manifol d set Pre s sure gau ge Indoo r unit Ou tdoor u nit Lo Hi Charge hose Nitr ogen g as cyli nder ( in vert ic al st a nding p osition ) To avoid nitrogen entering the refrigerant system in a liquid state, the top of the cylinder must be higher than its bottom then you pressurise the system. Usually, the cylinder is used in a vertical standing position. Do a leak test of all joints of the tubing (both indoor and outdoor) and both gas and liquid side service valves. Be sure to wipe off the soap with a clean cloth. After the system is found to be free of leaks, relieve the nitrogen pressure by loosening the charge hose connector at the nitrogen cylinder. When the system pressure is reduced to normal, disconnect the hose from the cylinder. Apply a soap water or a liquid neutral detergent 15 GD Midea Refrigerant Equipment Co. Ltd Service manual for Electrolux split Series on the indoor unit connection or outdoor unit connections using a soft brush to check for leakage of the connecting points of the piping. If bubbles come out, the pipes have leakage. Note: A: Lo stop valve B: Hi stop valve C and D: connections to the indoor unit. Indoor unit Outdoor unit M anifold set Pre s sure gau ge 2. 7. 2. 3 Evacuation Connect the charge hose end described in the preceding steps to the vacuum pump to evacuate the tubing and indoor unit. [. . . ] The inlet and outlet valve of the compressor is damaged, making the low Capillary tube Compressor pressure connected with the high pressure. The refrigerating system is difficult to produce high pressure and low pressure. Replace the compressor after checking for the reason. Heat sources Water drainage failure The indoor unit is Water drops from indoor unit incorrect installed Drainage pipe blocked The humidity in room is too high Wiring failure Zero-crossing error Wire EMC Outdoor PCB failure Reduce if over loaded. Check the drainage pipe and repair if failure. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EXS18GC4WE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EXS18GC4WE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag