If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EXS24HC2WI. We hope that this AEG-ELECTROLUX EXS24HC2WI user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX EXS24HC2WI.


Mode d'emploi AEG-ELECTROLUX EXS24HC2WI
Download
Manual abstract: user guide AEG-ELECTROLUX EXS24HC2WI

Detailed instructions for use are in the User's Guide.

[. . . ] ROOM AIR CONDITIONER INSTALLATION MANUAL (Split Type) Please read this installation manual completely before installing the product. When the power cord is damaged, replacement work shall be performed by authorized personnel only. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Contact the authorised service technician for repair or maintenance of this unit. CONTENTS SAFETY PRECAUTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 INSTALLATION OF INDOOR AND OUTDOOR UNITS. . . . . . . . . . . . . . . . . . . . . . . 3 ELECTRICAL WORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 AIR PURGING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 TEST RUNNING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Be careful not to let the drain hose slack. Heat insulated both of the auxiliary piping. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit. Never intercross nor intertwist the power wire with any other wiring. Run the drain hose sloped downward to drain out the condensed water smoothly. OUTDOOR UNIT INSTALLATION Outdoor installation precaution Install the outdoor unit on a rigid base to prevent increasing noise level and vibration. Determine the air outlet direction where the discharged air is not blocked. In the case that the installation place is exposed to strong wind such as a seaside, make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates. Specially in windy area, install the unit to prevent the admission of wind. If need suspending installation, the installation bracket should accord with technique requirement in the installation bracket diagram. The installation wall should be solid brick, concrete or the same intensity construction, or actions to reinforce, damping supporting should be taken. The connection between bracket and Strong wall, bracket and the air conditioner should be wind firm, stable and reliable. If there is serious safety problem about the power supply, the technicians should refuse to install the air conditioner and explain to the client until the problem is solved. Power voltage should be in the range of 90%~110%of rated voltage. The creepage protector and main power switch with a 1. 5 times capacity of Max. Current of the unit should be installed in power circuit. Ensure the air conditioner is grounded well. According to the attached Electrical Connection Diagram located on the panel of the outdoor unit to connect the wire. All wiring must comply with local and national electrical codes and be installed by qualified and skilled electricians. An individual branch circuit and single receptacle used only for this air conditioner must be available. See the following table for suggested wire sizes and fuse specifications: 9 Electrical work Model 9000Btu/h 10000Btu/h Model 12000Btu/h Power supply 220-240V~ 50Hz or 220-230V ~ 60Hz Input Rated Amp (Switch/Fuse) 16A 16A Power Cord Size 2 1. 0mm2 /1. 5mm 1. 5mm2 NOTE: The supply voltage should be consistent with the rated voltage of the air conditioner. Indoor/Outdoor connection cable should be H07RN-F type. [. . . ] Make Low pressure valve sure the pressure display in the pressure indicator is a little higher than the atmosphere pressure. Remove the charge hose from the Low pressure charge hose. Fully open the packed valve stems B and A. Securely tighten the cap of the packed valve. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EXS24HC2WI

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EXS24HC2WI will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag