User manual AEG-ELECTROLUX LUX LV1-2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX LUX LV1-2. We hope that this AEG-ELECTROLUX LUX LV1-2 user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX LUX LV1-2.


Mode d'emploi AEG-ELECTROLUX LUX LV1-2
Download
Manual abstract: user guide AEG-ELECTROLUX LUX LV1-2

Detailed instructions for use are in the User's Guide.

[. . . ] Wires must be trapped between black clamp and brass terminal. Securely tighten all 7 electrical terminal screws. These diagrams are provided for new installations or unreferenced wires. CAG1500 SERIES SET SUNDAY HEAT OFF WEEKDAY PROGRAM SET DAY/TIME COOL Easy as 1­2­3 HEATING SYSTEMS JUMPER PROVIDED COOLING SYSTEMS JUMPER PROVIDED G Y W RH RC B O G Y W RH RC B O Installs Easily Set Day and Time Choose Heat or Cool LUX PRODUCTS CORPORATION Mt. Laurel, New Jersey 08054, USA 43371 G W WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only. Energizer® is a registered trademark of Eveready Battery Company, Inc. [. . . ] When the keys are locked, a padlock icon will be visible above the time and temperature display. The Lock will be disabled after a Hardware Reset. MO NITE FAN HEAT 24 VOLT HEAT TRANSFORMER 120 VAC WEEKDAY PROGRAMMING 1. Select HEAT or COOL with the mode switch. You will see the display shown here: PROGRAM MO MORN START AT AM 1:30 70 120 HEAT SET FILTER 3 WIRE SYSTEM COOL ONLY G Y W RH RC B JUMPER O 6:00 70 HEAT SET SETUP OPTIONS JUMPER SETTINGS There are four jumpers, each controls a setting depending on its position. CAUTION The CAG1500 is protected against normal static electric discharges. To minimize the risk of damaging the unit in extremely dry weather, touch a grounded metal object before touching your thermostat. FAN A/C COMPRESSOR 24 VOLT COOLING TRANSFORMER 120 VAC INSTALLATION Please read all instructions carefully before beginning installation. 4 WIRE SYSTEM HEATING AND COOLING CAUTION Turn off electricity to the appliance before installing or servicing thermostat or any part of the system. Do not turn electricity back on until work is completed. G Do not short (jumper) across electric terminals on furnace or air conditioner to test the system. This may damage the thermostat and void your warranty. G All wiring must conform to local codes and ordinances. G The thermostat should be limited to a maximum of 1. 5 amps; higher current may cause damage to the thermostat. G Your thermostat is a precision instrument. Replace the batteries when the battery REPLACE indicator appears in the display or at least once a year. Switch electricity to the furnace and air conditioner OFF. To access your units batteries remove the unit from the wall by pressing up on the thumb latch at the bottom of thermostat and swinging the body up and away. Install two new Energizer or DURACELL "AA" size alkaline batteries in the battery compartment. Observe the polarity marking shown in the compartment. Hang the top of the unit by the tabs at the top corners of the base, then snap the bottom of the unit into place. If the body does not snap into place easily, remove the body, re-hang it from the tabs and try again. Turn the power back on to your heating and/or air conditioning system. If this is the first time you are installing batteries, the thermostat will display "SUN 12:00 AM". Within 90 seconds the thermostat will begin to display the room temperature alternately with the time. To correct the display, see "Setting the TIME and DAY, " after you set the programs. G Y W ADD JUMPER RH RC B* JUMPER O* MON DAY EVE NIGHT MORN DAY EVE NIGHT MORN FRI TUES SAT FAN HEAT PUMP 24 VOLT HEAT TRANSFORMER 120 VAC CHANGEOVER HEAT CHANGEOVER COOL WED DAY EVE NIGHT SUN CAUTION Read instructions carefully before removing any wiring from existing thermostat. [. . . ] Eastern Standard Time, Monday through Friday. The number is (856) 234-8803. MOUNTING THE CAG1500 Y W 1. (9. 5mm) bare wire ends and clean off any corrosion. Fill wall opening with noncombustible insulation to prevent drafts from affecting the thermostat. NOTE WARRANTY Limited Warranty: If this unit fails because of defects in materials or workmanship within one year of date of original purchase, LUX will, at its option, repair or replace it. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX LUX LV1-2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX LUX LV1-2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag