User manual AEG-ELECTROLUX LUX TX500B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX LUX TX500B. We hope that this AEG-ELECTROLUX LUX TX500B user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX LUX TX500B.


Mode d'emploi AEG-ELECTROLUX LUX TX500B
Download
Manual abstract: user guide AEG-ELECTROLUX LUX TX500B

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION Please read all instructions carefully before beginning installation. TOOLS REQUIRED #1 Phillips screwdriver (small) Drill with 3/16-in. (4. 8mm) bit CAUTION To avoid electrical shock and to prevent damage to the furnace, air conditioner, and thermostat, disconnect the power supply before beginning work. This can be done at the fuse box, at the circuit breaker, or at the appliance. TX500b SERIES SMART TEMP ELECTRONIC THERMOSTAT MORN DAY EVE NIGHT PM MO H E A T ® OFF UP MORN DAY EVE NIGHT MO DOWN H E A T PM UP MORN DAY EVE NIGHT MO H E A T PM UP DOWN DOWN SET WEEKDAY PROGRAM SET SUNDAY PROGRAM RESET FAN AUTO ON HEAT OFF COOL SET WEEKDAY PROGRAM SET SUNDAY PROGRAM RESET FAN AUTO ON HEAT OFF COOL HOLD HOLD SET DAY/TIME RUN NEXT SET DAY/TIME RUN NEXT Patents Pending 500 Patents Pending 500 SIMPLIFIED INSTRUCTIONS TO SET TIME & DAY · Rotate Dial to set DAY/TIME. [. . . ] WARNING: Use Energizer or DURACELL Alkaline Batteries Only. ® ® 3. Press up on the button on bottom of thermostat and swing the body away from the base and up to remove the body from the base. Be careful not to drop the body or disturb electronic parts. Leave the cover closed while the body is being removed from the base. Terminals C A U T I O N Base G Y W RH RC · Your thermostat is a precision instrument. · Turn off electricity to the appliance before installing or servicing thermostat or any part of the system. Do not turn electricity back on until work is completed. · Do not short (jumper) across electric terminals at control on furnace or air conditioner to test the system. This will damage the thermostat and void your warranty. · All wiring must conform to local codes and ordinances. · This thermostat is designed for use with 24 volt and millivolt systems. The thermostat should be limited to a maximum of 1. 0 amps; higher amperage may cause damage to the thermostat. If you are in doubt, call your utility company. C A U T I O N R W If you are mounting the base to a soft material like plasterboard or if you are using the old mounting holes, the screws may not hold. (4. 8mm) hole at each screw location, and insert the plastic anchors provided. Then mount the base as described. NOTE G Latch Button Screw Anchors (2) © COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED ATTACHING WIRES 4. Hold the base against the wall, with the wires coming through wherever it is convenient for wiring. Route the wires to below the terminal block. Position the base for best appearance (to hide any marks from an old thermostat). Attach the base to the wall with the two screws provided. TYPICAL COOLING AND HEATING SYSTEM (4-WIRE) G Y W RH RC TYPICAL COOLING AND HEATING SYSTEM (5-WIRE) G Y W RH RC FAN FAN Do not allow wires to touch each other or parts on thermostat. Wires must be trapped between black spacer and brass terminal. Also, be sure to tighten securely all 5 electrical terminal screws. C A U T I O N GAS VALVE GAS VALVE COOL COMP 24 VAC HEAT TRANSFORMER 110 Figure 10 COOL COMP REMOVE JUMPER BETWEEN RH & RC 24 VAC HEAT TRANSFORMER 110 24 VAC COOL TRANSFORMER Figure 11 WIRING DIAGRAMS 110 INSTALLING BATTERIES/ MAINTENANCE The TX500 requires two new Energizer ® or DURACELL ® "AA" size alkaline batteries to operate your furnace and retain its programming in memory. Replace the batteries when the LO BATT indicator appears in the display or at least once a year. If you have an electric system and the blower does not operate after installation, find the electric/gas heat selector on the back of the body. Move the selector to the ELEC position. NOTE DAY 1. [. . . ] A blank programming chart is provided below for you to record your temperature settings in that chart. Select HEAT to program the TX500 for controlling your heater. OR Select COOL to program the TX500 for controlling your air conditioner. MO TU WE TH FR HEAT OFF COOL MORN DAY EVE NIGHT H E A T AM 5 MIN/2 MIN MINIMUM ON/OFF TIME Your thermostat has an internal timer built in to protect your compressor. The timer forces a minimum on/off time of 5 minutes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX LUX TX500B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX LUX TX500B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag