If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX MC125-D/GB. We hope that this AEG-ELECTROLUX MC125-D/GB user guide will be useful to you.
Lastmanuals help download the user guide AEG-ELECTROLUX MC125-D/GB.
Manual abstract: user guide AEG-ELECTROLUX MC125-D/GB
Detailed instructions for use are in the User's Guide.
[. . . ] The relay also controls the condenser fans (M2. 2). MV17 has only one compressor and therefore no delay relay. At compressor operation the air circulates in the machine compartment from the air supply grille, through condenser and is discharged at the back. When the compressor standstill this flow is reversed in order to clean the condenser surface. [. . . ] When the compressor standstill this flow is reversed in order to clean the condenser surface. Temperature, pressure and flow for the system during operation when the thermostat cuts-out are shown on page 8.
Design and testing
The cabinet is CE-marked and complies with valid EUdirectives (low voltage directive and electro magnetic compatibility directive). All cabinets have been tested regarding electrical earthing and insulation. They have also been tested (pressure tested) regarding the evaporator and condenser. The cabinet has been test run regarding function and leakage.
Service and repair
Service and repair (except cleaning) must only be made by persons qualified to carry out service work on the product and who knows the function and design of the cabinet. These are responsible that the safety is not impaired. Special notice should be attended to · earth connection · insulation resistance · exchanged components must be equivalent with the original component When servicing the refrigerant circuit please note that · the work must only be done by persons with certified competence, and in accordance with national regulations. · the refrigerant must not be discharged to the atmosphere · Discharging and charging of refrigerant must be made through the schrader valve, with the refrigerant in liquid phase · Charging with another refrigerant than the stated must not be made without the approval of Carrier.
Defrost
The frost is melted with the help of air circulation from the evaporator fans, which operates also during defrost. Defrost is initiated by the defrost timer, which via the relay cuts out the compressors. Defrost is terminated by the defrost timer when the set time has elapsed. Remount in reversed order.
Repair instruction
Replacement of compressor
· Move the service pipe with the schrader valve to the new compressor · Always exchange the drier
Replacement of thermostat
· · · · · · · · · · · ·
Carefully lift and remove the front glass. Loosen the 3 screws, placed in the slot for the front glass. Loosen the 2 screws under the lower front. Remove the sealing of the bulb tube, and which is inserted at the back of the cabinet. Loosen the 2 cables on the thermostats left side. Put back the thermostat knob.
Replacement of condenser fan
Loosen the lower front (see replacement of thermostat). Loosen the compressor by loosening the 3-spring pins. Lift the compressor carefully a little outward. Remount in reversed order.
36 23 501-01 (A)
3
MC17/MV17 MC25
1
2
3
36 23 501-01 (-)
4
Prel. Technical Data
Storage temperature
Temperature °C
Average air temperature Average temperature visible products Air inlet Air return Tested according to EN 441 Comments: (*) = night blinds down for 14h out of 24h Normal settings: Thermostat operation Defrost timer **Options: Power consumption of the light box: Power consumption of the endwall lighting: Power consumption of the heating rod: Pos 1, 5 4h/20 min + 41 W + 82 W + 500 W
Wall cabinet MC17-SA
0°C/+1°C
Climate class
+25°C/60%RH +30°C/55%RH +1 +4 +4 +8 +1 +5 +7 +11
Main data
Display area Refrigerated net volume Length Width (Depth) Height/With castors Floor area Max. [. . . ] Remount in reversed order.
36 23 501-01 (A)
3
MC17/MV17 MC25
1
2
3
36 23 501-01 (-)
4
Prel. Technical Data
Storage temperature
Temperature °C
Average air temperature Average temperature visible products Air inlet Air return Tested according to EN 441 Comments: (*) = night blinds down for 14h out of 24h Normal settings: Thermostat operation Defrost timer **Options: Power consumption of the light box: Power consumption of the endwall lighting: Power consumption of the heating rod: Pos 1, 5 4h/20 min + 41 W + 82 W + 500 W
Wall cabinet MC17-SA
0°C/+1°C
Climate class
+25°C/60%RH +30°C/55%RH +1 +4 +4 +8 +1 +5 +7 +11
Main data
Display area Refrigerated net volume Length Width (Depth) Height/With castors Floor area Max. load, bottom 3. 3 1040 1700 850 1990/2110 1. 6 200 300 m² dm³ mm mm mm m² kg/m2 kg/m2
Installation data
Electrical supply* Voltage range Fuse Power consumption** Operating current Defrost power consumption Defrost current Energy consumption (at +25°C/60%RH) Heat dissipation Refrigerant charge Sound level Maximum ambient climate Minimum ambient temperature 230 220-240 16 2100 10. 0 410 3. 0 42. 0(*29. 0) 1700 R404A Compr. 1=0. 750 Compr. 2=0. 800 61 +30°C/55 +15 V 50Hz V A HRC W A W A kWh /24h W kg kg dB(A) RH °C
Transport
Length x Width x Height (measurements incl. packing 1805x920x2165 mm 370 kg
1700
40
450 575 500
1400 500 650
725 850
All rights reserved We reserve the right to change specifi- cations without prior notice and to use alternative competitive designs of sub components
tdatdc. wk4 English 960402
1990
Page Issue Translated
1 IBA
(1)
Prel 9 20030217
36 23 119-03 (Prel. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX MC125-D/GB
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.