User manual AEG-ELECTROLUX MC17-MV17

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX MC17-MV17. We hope that this AEG-ELECTROLUX MC17-MV17 user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX MC17-MV17.


Mode d'emploi AEG-ELECTROLUX MC17-MV17
Download
Manual abstract: user guide AEG-ELECTROLUX MC17-MV17

Detailed instructions for use are in the User's Guide.

[. . . ] For MC17 and MC25, there is a thermostat (S1, see page 9) which controls both the timer (S4) and the both compressors (M1. 1 and M1. 2) for regulation of the temperature. The control of the timer means defrost interval based on the compressor operation time. Compressor 2 (M1. 2) is controlled by the relay (K1), which is controlled by the thermostat and a relay. [. . . ] Influence of draught and/or heating sources?Operation sensor defective (or incorrect set)?Compressor defective? · · · · Insert the bulb tube through the right hole. Bend the tube a little upwards and follow the ceiling until the tube comes out on the back of the cabinet. Insert the bulb tube in the plastic tube until it reaches the bottom. Remount in reverse order according to the first 4 points. Replacement of fluorescent tube end wall · · · Loosen the light sheet by loosening the 4 screws holding it. Remount in reversed order. Defrost problems · Defective defrost sensor (no defrost)?· The thermostat is set colder than pos. 3? Replacement of fluorescent tube in light box (This is only valid for MC17 and MV17) · · · · · · · · · · · · · · · · · · · · · · · Loosen the light box, by loosening the 3 screws on the roof holding the light box. Pull carefully apart the quick connection and remove the light box. Loosen the 2 screws, underneath the light box, which holds the end wall of the light box. Loosen the screw, underneath the box, which holds the opal sheet. Remount in reversed order. Summary of warranty conditions Faults occurring during the warranty period are covered by the warranty with the exception of; · Transport damages and fair wear and tear · Adjustment of thermostat and timer · Fuses, fluorescent tubes, starters or similar · Problems in connection with an incorrect installation, abnormal use and non-maintenance. Replacement of mains cable Loosen the lower front (see replacement of thermostat) Loosen the 2 screws holding the mains cable. Fasten one thread or similar in the mains cable (to simplify the reassemble). [. . . ] load, bottom 3. 3 1040 1700 850 1990/2110 1, 6 200 300 m² dm³ mm mm mm m² kg/m2 kg/m2 Installation data Electrical supply* Voltage range Fuse Power consumption** Operating current Defrost power consumption Defrost current Energy consumption (at +25°C/60%RH) Heat dissipation Refrigerant charge Sound level Maximum ambient climate Minimum ambient temperature 230 220-230 16 2350 11. 2 450 3. 2 42. 0(*29. 0) 1700 R404A Compr. 1=0. 800 Compr. 2=0. 825 62 +30°C/55 +15 V 60Hz V A HRC W A W A kWh /24h W kg kg dB(A) RH °C Transport Length x Width x Height (measurements incl. packing 1805x920x2165 mm 370 kg 1700 40 450 575 500 1400 500 650 725 850 All rights reserved We reserve the right to change specifi- cations without prior notice and to use alternative competitive designs of sub components tdatdc. wk4 English 960402 1990 Page Issue Translated 1 IBA (1) Prel 1 20030217 36 23 119-05 (A) Prel. Technical Data Storage temperature Temperature °C Average air temperature Average temperature visible products Air inlet Air return Tested according to EN 441 Comments: (*) = night blinds down for 14h out of 24h Normal settings: Thermostat operation Defrost timer **Options: Power consumption of the light box: Power consumption of the endwall lighting: Power consumption of the heating rod: Pos 1 4h/20 min + 41 W + 82 W + 350 W Wall cabinet MV17-SA +2°C/+3°C Climate class +25°C/60%RH +30°C/55%RH +3 +6 +4 +9 Main data Display area Refrigerated net volume Length Width (Depth) Height/With castors Floor area Max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX MC17-MV17

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX MC17-MV17 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag