User manual AEG-ELECTROLUX MC9-MV9

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX MC9-MV9. We hope that this AEG-ELECTROLUX MC9-MV9 user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX MC9-MV9.


Mode d'emploi AEG-ELECTROLUX MC9-MV9
Download
Manual abstract: user guide AEG-ELECTROLUX MC9-MV9

Detailed instructions for use are in the User's Guide.

[. . . ] The temperature is controlled by a thermostat (S1, see page 9) which controls both timer (S4) and also the relay (K1). The control of the timer means defrost interval based on the compressor operation time. The relay then controls the compressor (M1) and the condenser fans (M2. 2). [. . . ] At defrost the product temperature rises with some degree. Settings (Set values see "Technical Data") Operating thermostat The thermostat is set using the knob in the thermostat house, so that the knob figure points to the index on the panel plate. 36 23 199-01 (F) 2 MC9/13 MV9/13 Common reasons for disturbances in operation Temperature too high · · · · · · · · · · Mains fuse blown due to other equipment also being connected. Influence of draught and/or heating sources?Operation sensor defective (or incorrect set)?Compressor defective? · · · Insert the bulb tube in the plastic tube until it reaches the bottom. Remount in reverse order according to the first 4 points. Replacement of fluorescent tube end wall · · · Loosen the light sheet by loosening the 4 screws holding it. Remount in reversed order. Replacement of fluorescent tube in light box · · · · · · · · Loosen the light box by loosening the 3 screws on the roof holding the light box. Pull carefully apart the quick connection and remove the light box. Loosen the 2 screws, underneath the light box, which holds the end wall of the light box. Loosen the screw, underneath the box, which holds the opal sheet. Remount in reversed order. Defrost problems · Defective defrost sensor (no defrost)?· The thermostat is set colder than pos. 3? Summary of warranty conditions Faults occurring during the warranty period are covered by the warranty with the exception of; · Transport damages and fair wear and tear · Adjustment of thermostat and timer · Fuses, fluorescent tubes, starters or similar · Problems in connection with an incorrect installation, abnormal use and non-maintenance. Replacement of horizontal fluorescent tube · When exchanging the horizontal fluorescent tube, it has to be replaced by a fluorescent tube with a protective film. Repair instruction Replacement of compressor · Move the service pipe with the schrader valve to the new compressor · Always exchange the drier · · · · · · · · · · · · · · · Replacement of mains cable Loosen the lower front (see replacement of thermostat) Loosen the 2 screws holding the mains cable. Fasten one thread or similar in the mains cable (to simplify the reassemble). Pull out the mains cable from the back of the cabinet. Pull the thread from the front of the cabinet. Remount in reversed order. Replacement of thermostat · · · · · · · · · · · · · Carefully lift and remove the front glass. Loosen the 3 screws, placed in the slot for the front glass. Loosen the 2 screws under the lower front. [. . . ] load, bottom 1. 2 520 890 850 1990 0. 8 200 300 m² dm³ mm mm mm m² kg/m2 kg/m2 Installation data Electrical supply* Voltage range Fuse Power consumption Operating current Defrost power consumption Defrost current Energy consumption (at +25°C/60%RH) Heat dissipation Refrigerant charge Sound level Maximum ambient climate Minimum ambient temperature 230 220-240 10 950 5. 5 210 1. 5 21. 0 (*15. 5) 875 R404A 0. 750 56 +30°C/55 +15 V 50Hz V A HRC W A W A kWh /24h W kg dB(A) RH °C Transport Length x Width x Height (measurements incl. packing 990x905x2130 mm 205 kg 890 40 450 1400 500 500 650 725 850 1990 All rights reserved We reserve the right to change specifications without prior notice and to use alternative competitive designs of sub components tdatdc. wk4 English 960402 Page Issue Translated 1 2 IBA (1) 20020111 20010110 36 23 119-11(B) Technical Data Storage temperature Temperature °C Average air temperature Average temperature visible products Air inlet Air return Tested according to EN 441 Comments: (*) = night blinds down for 14h out of 24h Normal settings: Thermostat operation (Cut-out -1. 0°C, diff 5°C) Defrost timer * 230 V 60 Hz version also available Wall cabinet MC13-SA 0°C/+1°C Climate class +25°C/60%RH +30°C/55%RH +1 +4 +4 +8 -1 +3 +5 +9 Pos 1, 5 4h/20 min Main data Display area Refrigerated net volume Length Width (Depth) Height Floor area Max. load, bottom 2. 7 750 1250 850 1990 1. 1 200 300 m² dm³ mm mm mm m² kg/m2 kg/m2 Installation data Electrical supply* Voltage range Fuse Power consumption Operating current Defrost power consumption Defrost current Energy consumption (at +25°C/60%RH) Heat dissipation Refrigerant charge Sound level Maximum ambient climate Minimum ambient temperature 230 220-240 10 1600 7. 5 260 1. 7 33. 5 (*24. 0) 1400 R404A 1. 100 61 +30°C/55 +15 V 50Hz V A HRC W A W A kWh /24h W kg dB(A) RH °C Transport Length x Width x Height (measurements incl. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX MC9-MV9

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX MC9-MV9 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag