Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX RC1500EG. We hope that this AEG-ELECTROLUX RC1500EG user guide will be useful to you.
Lastmanuals help download the user guide AEG-ELECTROLUX RC1500EG.
Manual abstract: user guide AEG-ELECTROLUX RC1500EG
Detailed instructions for use are in the User's Guide.
[. . . ] Igniting the gas burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 12. Shutting down gas operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 13. Food and drink storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 14. Ice-making. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 15. [. . . ] It is a regular earthed plug for connection to a regular earthed socket. Due to the difference in the plugs used, an adapter will be necessary for other countries. If the fuse requires replacing at any time, the fuse cover/carrier should be removed using a small screwdriver to lever it out. The old fuse should be replaced by a 3-amp, ASTAapproved, BS 1362 fuse and the fuse cover/carrier must be refitted before the plug is used again. If the fuse cover/carrier is lost, a replacement can be obtained from the Electrolux Service shops and offices. The fuse cover/carrier must be of the same colour as that of the coloured insert in the base of the plug. Under no circumstances must the plug be used without a correct fuse cover/carrier fitted. If the plug supplied on the mains lead is not suitable for the socket in your home, it should be cut off and disposed of safely, or destroyed, to avoid any possible shock hazard resulting from the plug being inserted into a 13-amp socket elsewhere in the house. A suitable replacement plug should then be fitted as given below. General guide to fitting any plug Ensure the lengths of wire inside the plug are prepared correctly. Connections should be firmly made after all conductor strands are entered into the terminal posts. If the unit is equipped with a special car plug (with adapter), the adapter can be removed to correspond to the various plug connectors: Click off by turning in the opposite direction to the arrow and pull off axially. When using battery operation, the cooling performance is not thermostatically regulated, i. e. Only units exclusively equipped for use with one of the two electrical operation methods - A/C or D/C - can, in general, be thermostatically regulated by using knob A in the relevant operation method. When knob A is ineffective or if the temperature is unnecessarily too low: Turn unit off Pull out plug from socket.
8. Liquid gas operation
Do not use any additional form of energy (mains/battery). The unit must not be connected to town or natural gas pipelines. It is only suitable for use with propane/butane gas (e. g. Calor gas, camping gas, caravan gas, etc. ). The mobilCooler is equipped for a specific gas-pressure, corresponding to the standard pressure of the country in which it is sold. The rating-plate states the pressure which is correct. It is important that a non-adjustable pressure regulator is used to reduce the pressure in the gas cylinder to the operating pressure specified on the rating-plate, no other pressure may be used. [. . . ] After defrosting, the cooler should be cleaned carefully and dried. To avoid any unpleasant smells forming in the cooler, the lid should be left slightly open.
16. Measures after prolonged periods of disuse
Should the mobile cooler not function correctly after being switched on, place the unit upside down WITHOUT ANY CONNECTING POWER SUPPLY. After a few minutes, return the mobile cooler to its correct position and switch on again. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX RC1500EG
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX RC1500EG will begin.