User manual AEG-ELECTROLUX RH330LD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX RH330LD. We hope that this AEG-ELECTROLUX RH330LD user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX RH330LD.


Mode d'emploi AEG-ELECTROLUX RH330LD
Download
Manual abstract: user guide AEG-ELECTROLUX RH330LD

Detailed instructions for use are in the User's Guide.

[. . . ] Servicing must only be carried out by authorised service personnel. 2. 2 Ammonia is used as the coolant. This is a natural compound which is also present in common household cleaners (1 litre of salmiac cleaner contains up to 200g of ammonia - this is roughly double the amount contained in the cooling unit). If a leak occurs (which can be easily detected due to the unpleasant smell): Switch the device off (pull mains plug, if applicable); Ventilate room thoroughly. [. . . ] Tighten screw. 6 4. 7 Connecting the Device to the Electricity Supply The device must be connected to a properly earthed socket in line with the relevant valid country regulations. Check prior to initial operation that the voltage noted on the model label corresponds to the mains voltage. If this is not the case, do not connect the device and contact your dealer! 4. 7. 1 Plug connection (for United Kingdom only) Warning - This appliance must be earthed. IMPORTENT Attention: For GB Only ! If a 3-pin plug is used, it should be fitted with a 3 amp fuse, with other plug types, the circuit should contain a 5 amp fuse. The wires in the mains lead of this appliance are coloured in accordance with the following code: GREEN and YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows. Connect the GREEN and YELLOW coloured wire to the plug terminal marked letter E or earth symbol or coloured green or green and yellow. Connect the BROWN coloured wire to the plug terminal marked letter L or coloured red. Connect the BLUE coloured wire to the plug terminal marked letter N or coloured black. Moulded-On Plug Version The mains lead is fitted with a non-rewirable moulded-on plug containing a 3 amp fuse. If the fuse requires replacing at any time, the fuse cover/carrier should be removed using a small screwdriver to level out. The old fuse should be replaced by a 3 amp ASTA approved BS1362 fuse and the fuse cover/carrier must be refitted before the plug is used again. If the fuse cover-carrier is lost, a replaceement can be obtained from the Electrolux service Shops. The fuse cover/carrier must be of the same colour as that of the coloured insert in the base of the plug. In no circumstances must the plug be used without a correct fuse cover/carrier fitted. 7 If the plug supplied on the mains lead is not suitable for the socket in your home, it should be cut off and disposed of safely, or destroyed, to avoid any possible shock hazard resulting from the plug being inserted into a 13 amp socket elswhere in the use. A suitable replacement plug should then be fitted as given above. 4. 8 Changing the Sliding Hinge (possible with RH330, RH340, RH341, RH360, RH136, RH137) 1. 2. 1. 2. 3. 4. Distance to cupboard door (A) 1. When closed, the cupboard door (A) must not lie against the rest of the surrounding cupboard area (distance 1-2mm). There must be a distance of 6-8mm between the cupboard door and the miniBar. 8 4. 9 Changing the Doorhang ( RH136D, RH137D, RH330, RH340, RH341, RH 360, RH 361) 1. L R 2. 3. 1. 2. 4. 5. 6. 7. 11. 12. 13. 9 5. 0 5. 1 INSTRUCTION FOR USE Initial Operation earthed socket. The device must be plugged into a properly The miniBar achieves its operating temperature after several hours. The miniBar operates silently ! 5. 2 min. Temperature Control max. The miniBar is fitted with an electronic temperature control. The thermostat control button is situated in the internal containers rear area. (RH 355LD, RH 356LD: the thermostat button is situated in the unrefrigerated compartment). 5. 3 Automatic Defrost Function (5. 1) and lasts for two hours. defrosting period of 2 hours . The first defrosting phase commences 15 hours after the initial operation After this, the device operates for 22 hours at a time, followed by a T S T S T The ice layer must never be removed using force, nor must the defrosting process ever be accelerated using a heater. 5. 4 Ice-Making B A 1. [. . . ] If possible, always store pre-cooled goods. Do not expose the miniBar to direct sunlight and do not place it close to a source of heat. An unobstructed air circulation in the fridge aggregate must be ensured. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX RH330LD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX RH330LD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag