User manual AEG-ELECTROLUX RH456LD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX RH456LD. We hope that this AEG-ELECTROLUX RH456LD user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX RH456LD.


Mode d'emploi AEG-ELECTROLUX RH456LD
Download
Manual abstract: user guide AEG-ELECTROLUX RH456LD

Detailed instructions for use are in the User's Guide.

[. . . ] The minibar is not suitable for the proper storage of medications. The miniBar must be installed in such a way that accidental contact with the cooling unit (which heats up when in use) is impossible. The appliance has to be connected to a properly earthed socket in line with the relevant valid country regulations. [. . . ] There sould be 20mm clearance to the wall 3. Ventilation must be provided as shown in alternatives A, B, C or D 4. The ventilation duct must at least measure 105mm x the wtdth of the refrigerator 5. Only the entire cooling unit must project into the duct as shown 6 Air passing through the duct must not be preheated by any source of heat 7. Ventilation grills, if used, must have openings of at least 200cm² each Where a socket outlet is used for the mains connection lead, the outlet must be freely accessible. 5 4. 6. 1 4. 6 Securing RH456LD/E 1. Put on cap. 4. 6. 2 RH430LD, RH440LD, RH441LD, RH460LD, RH461LD RH436D, RH447D, RH438(L)D, RH448(L)D The miniBar must be screwed onto the cupboard using the lower hinges. 1. Put on cap. 6 4. 7 Connecting the Device to the Electricity Supply The device must be connected to a properly earthed socket in line with the relevant valid country regulations. Check prior to initial operation that the voltage noted on the model label corresponds to the mains voltage. If this is not the case, do not connect the device and contact your dealer! If the connection cable is damaged it must be replaced by the Customer Service at Dometic, or by respectively qualified personnel, in order to prevent any hazards. 4. 7. 1 Attention: For GB Only ! Plug connection (for United Kingdom only) If a 3-pin plug is used, it should be fitted with a 3 amp fuse, with other plug types, the circuit should contain a 5 amp fuse. Warning - This appliance must be earthed. IMPORTANT The wires in the mains lead of this appliance are coloured in accordance with the following code: GREEN and YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows. Connect the GREEN and YELLOW coloured wire to the plug terminal marked letter E or earth symbol or coloured green or green and yellow. Connect the BROWN coloured wire to the plug terminal marked letter L or coloured red. Connect the BLUE coloured wire to the plug terminal marked letter N or coloured black. Moulded-On Plug Version The mains lead is fitted with a non-rewirable moulded-on plug containing a 3 amp fuse. If the fuse requires replacing at any time, the fuse cover/carrier should be removed using a small screwdriver to level out. The old fuse should be replaced by a 3 amp ASTA approved BS1362 fuse and the fuse cover/carrier must be refitted before the plug is used again. If the fuse cover-carrier is lost, a replaceement can be obtained from the Dometic service Shops. The fuse cover/carrier must be of the same colour as that of the coloured insert in the base of the plug. In no circumstances must the plug be used without a correct fuse cover/carrier fitted. . . . . . . 7 If the plug supplied on the mains lead is not suitable for the socket in your home, it should be cut off and disposed of safely, or destroyed, to avoid any possible shock hazard resulting from the plug being inserted into a 13 amp socket elswhere in the use. [. . . ] c. ) The fridge door does not close tightly. d. ) Light permanently on when door closed. e. ) The fridge was stocked a short while ago. e. ) Check fridge after 5-6 hours for proper cooling function. Failure : Frost formation in fridge. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX RH456LD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX RH456LD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag