User manual AEG-ELECTROLUX RM2210-1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX RM2210-1. We hope that this AEG-ELECTROLUX RM2210-1 user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX RM2210-1.


Mode d'emploi AEG-ELECTROLUX RM2210-1
Download
Manual abstract: user guide AEG-ELECTROLUX RM2210-1

Detailed instructions for use are in the User's Guide.

[. . . ] 12 STARTING THE REFRIGERATOR . . . . . . . . . . . . . . 12 REGULATING THE TEMPERATURE . . . . . . . . . . 12 TRAVEL CATCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 FOOD STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] To defrost the refrigerator, turn it off and remove the ice trays and the food item, leave the cabinet and freezer doors open. Do not try to accelerate defrosting by using any kind of heating appliance, as this might damage the plastic surfaces of the refrigerator. Neither should any sharp objects be used to scrape off the ice. Defrost water runs from a drip tray to a receptacle at the rear of the refrigerator where it normally evaporates. Heavy frosts build up on the freezer plate and the cooling fins, and a lot of defrost water: Move the plastic drain tube in to a watertight bucket or container. (Access through the lower ventilation grill on the outside of the vehicle). As the frost melts, the water will flow into the container. Replace the drain tube to its original position after defrosting. Defrost water in the freezer compartment should be mopped up with a cloth. When the ice has melted, wipe the refrigerator dry and restart it. Place the food items back inside but wait until the refrigerator is cold before making ice cubes. WINTER OPERATION Please check that the ventilation grilles are not blocked by snow, leaves etc. Inadequate ventilation of the cooling unit due to the intake and/or exhaust air vents being partly or completely blocked. Gas pressure is incorrect - please check the pressure regulator on the gas container. The door is not properly closed or the magnetic sealing strip is defective. If the refrigerator still does not work properly, call a service technician. The sealed cooling system must not be opened, since it contains corroding chemicals under high pressure. INSTALLATION INSTRUCTIONS REPOSITIONING THE HINGES The refrigerator is equipped with reversible doors. A special door reversing kit must be used to reverse the doors. For further information, contact your dealer or Electrolux. DOOR PANEL Door panels can easily be fitted or changed. The dimensions of the panels must be: Model RM 6501 Height upper door 265 ±1mm lower door 833 ±1mm Width 483 ±1mm Thickness max. 4 mm Before starting the mounting work, check that the panel dimensions are in compliance with those given in the table and the instructions are read thoroughly. When mounting the panel, proceed as follows: Upper door MAINTENANCE Always turn to a qualified service technician who is familiar with LP gas systems and refrigerator. We recommend that a service technician check the refrigerator once a year. · · · · · · · · · · · · · · · · remove the two screws holding the control panel, pull out the two knobs (energy selector and thermostat) unscrew the upper hinge pin and remove the door unscrew the upper part of the door frame, remove the old panel insert the new panel and push the panel downwards fasten the upper part of the door frame with its three screws please note that the panel must be changed on the lower door, before the upper door can be mounted Check all connections in the LP gas system for gas leaks. [. . . ] The connection is made to the terminal block (fig. To avoid a voltage drop, the cross section area of the connecting cable between battery/alternator and the refrigerator must be 10 mm2. To ensure satisfactory operation, the positive lead must be fitted with a fuse rated at max. To prevent the refrigerator from draining the battery, make sure that the current supplied to the caravan is cut off when the vehicle engine is not running, for example by fitting an ignition control relay. ELECTRICAL CONNECTION The electrical installation must be carried out in a proper and durable manner; taking into accounts all relevant regulations and codes of practice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX RM2210-1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX RM2210-1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag